2X16SP-1000BT
20
© 2007 Datacom Systems Inc
4.2
Hardware Installation
This section will focus on a simple configuration which describes the typical 2X16SP-
1000BT Gigabit SPAN Matrix Switch hardware installation at the network location of your
choice.
4.2.1
Power
This section will focus on power at the installation network location of the 2X16SP-1000BT
Gigabit SPAN Matrix Switch.
Two AC input power sockets are provided on the rear panel. The front panel
POWER 1
,
POWER 2
LEDs are illuminated
green
, respectively, when the AC power switch is depressed
ON
and AC power is available at both the two rear AC power sockets.
Step 1.
Using the supplied AC Line Cords, plug the 2X16SP-1000BT SPAN Matrix Switch
into different circuit external power sources. Although only one power supply is required to
power the 2X16SP-1000BT, use of a second independent power source is strongly
recommended to assure uninterrupted monitoring. Furthermore, connecting the second AC
power socket to a different external power source circuit than the first AC power source
eliminates power as a single point of failure.
The AC
POWER
switch is a rocker style switch. The AC power switch circle icon depressed
is
OFF
. The AC power switch bar icon depressed is
ON
..
Step 2.
Power
ON
the 2X16SP-1000BT by depressing the AC power switch bar icon. The
powered
ON
2X16SP-1000BT is indicated by the illuminated
green
POWER 1
and
POWER 2
LEDs on the front panel. Either
POWER 1
,
POWER 2
LED not illuminated when powered
ON
indicates a defective power source and immediate investigation as to the cause is required to
insure redundant power integrity.