1 • GENERAL SAFETY INFORMATION 

ATTENTION: It is prohibited to carry out any kind of assembly, repair or adjustment to the apparatus by 

unqualified staff, and if the necessary precautions haven’t been taken and electricity supply disconnected (including any back-up batteries), in order 

to avoid any possible accident or injury, DASPI will not be responsible for any damage or injury to people, animals or objects resulting from improper 

use of the apparatus or for use other than what is specified in this instruction booklet, and/or resulting from any modification carried out on this product 

and its components. This control panel is not suitable for installation in an explosive atmosphere. 

Keep this manual with care, enclose it to the technical 

installation file and keep them in a suitable an convenient place known by whoever is concerned, for future reference.

2 • PRODUCT TYPE 

The PIXEL control panel has been designed to operate a motor 24 Vdc for sliding gates. It is supplied with an electronic clutch and has a radio 

receiver incorporated. 

3 • TRIMMERS

TCA

Pause time from 1 to 120 seconds with trimmer set on the maximum TCA unable

OP PWR

Opening torque

CL PWR

Closing torque

4 • PROGRAMMING AND SETTING THE CONTROL PANEL 

Switching DIP-SWITCHES must always be carried out with control panel disconnected from the electricity mains

SW1

ON

OFF

1

To enable 3 seconds pre-opening flashing light 

No pre-opening flashing light

2

To disable START command while gate is opening (residential mode)

START command active also while gate is opening , the gate stops 

3

To activate additional feature “Close after passing through photocells”. 

Attention! This feature can be activated only with photocells connected to 

output 13-14

Function not activated

4

High sensitivity during slowing down

Low sensitivity during slowing down

5

To make terminal 17 to work as courtesy light output

To make terminal 17 to work as gate open warning light output

6

To activate PHOTOTEST feature. Attention! This feature can be activated only 

with photocells connected to output 12-13. Before each operation the control 

panel checks if contact of photocells is open. If not open flasher remains 

steadily on and the gate does not work.

Function not activated

LED TABLE

DL1

Red LED to indicate use of START button command on control panel

DL8

Red LED lights up when the SAFETY EDGE contact opens

DL2

Red LED indicates the programming input mode and the various phases 

that can be activated using the PRGM button on the control board

DL10

Red LED lights up when the FCC contact opens

DL3

Green LED lights up when the PED contact closes.

DL11

Red LED lights up when the FCA contact opens

DL4

Green LED lights up when the START contact closes

LED1

Red LED indicates of radio codes

DL6

Red LED lights up when the STOP contact opens

LED2

Red LED indicates of radio codes on PED button or the cancellation of 

existing ones

DL7

Red LED lights up when PHOTO contact opens. With photocells 

connected to output 12-13 and gate still it remains lit up; it switches off 

when gate starts and it lights up again at the opening of the photocell 

contact.

In case LED indications do not match the table above, check connections and proper order of connected devices.

5 • RECEIVER 

433.92 MHz radio receiver Storing capacity up to 256 remote controls (Tx) with different codes.

STORING REMOTE CONTROLS. 

After connecting to the electricity mains the control panel, LED2 should lights up for 1 second.

If this does not light up, or if both 

LED1

 and 

LED2

 simultaneously light up, contact Customer Services. 

1 - 

Press INS button on the panel for storing a START command,

 or press 

DEL/PED

 on the panel for storing a pedestrian command. 

LED2

 lights up. 

2 - Push the desired remote control button twice to store the radio code. The first push will make 

LED2

 turns off and then on, while the second push will make 

LED2

 

flash 3 times to indicate that radio code has been stored. If something goes wrong, the procedure terminates without the 3 flashes of 

LED2

.

Once INS or 

PED/DEL

 button on the receiver has been pressed and after the first push on remote control storing procedure must be complete in 10 seconds. In 

case the same remote control button is mistakenly stored for both 

START

 and 

PED

 pedestrian command , the gate won’t work and 

LED1

 will flash. If this occurs, t 

code must be deleted (as described below) and stored again in the correct command.

DELETING RADIO CODES

Keep 

DEL/PED

 button pressed for 5 seconds: 

LED1

 and 

LED2

 will light up. From now on deleting procedure is the same as storing procedure: 

Push the remote control button twice to delete radio code. The first push will make 

LED2

 turns off and then on, while the second push will make 

LED2

 flash 3 times 

to indicate that radio code has been deleted. If something goes wrong, the procedure terminates without the 3 flashes of 

LED2

.

Once 

INS

 or 

PED/DE

L button on the receiver has been pressed and after the first push on remote controlstoring procedure must be complete in 10 seconds.

DELETING ALL RADIO CODES

Keep 

DEL/PED

 button pressed for 10 seconds: 

LED1

 and 

LED2

 will flash 3 times to indicate that all radio codes have been deleted.

N.B. If inputs which are normally closed (N.C.) are not being used, they must be bridged. If more than one N.C. contacts are used on the same terminal inputs, 

they must be connected in series. If more than one N.O. (normally open) contacts are used on the same input they must be connected in parallel.

EN

1

2

Antenna input to connect the ‘hot’ pole of the antenna to terminal 1 

and the braid to terminal 2 

13

14

Permanent output power to photocells. Attention! Use only with 

feature PHOTOTEST disabled DIP6 = OFF otherwise the gate won’t 

work and the blinker lights up steadily. 14+/13- (max 150mA)

3

PED Input activates pedestrian opening when the gate is closed and 

it closes the gate when it is open.

15

13

Output for additional accessories 24Vdc 13-/15+ (max. 500mA) 

4

5

START input open the gate when it is closed, it stops the gate while 

opening (if DIP2 = OFF), it closes the gate when the gate is opening, 

and open during closing

15

16

Flashing light output: intermittent output 24Vd DC max 10W

5

6

STOP Input. If activated it stops every movement.

15

17

SPIA Output DIP5 = OFF, fast flashing light during closing, slow flashing 

during opening, continuous light when gate is open, flasher switched 

off when gate is closed

7

9

PHOTO input with DIP3 = OFF gate reverses movement during closing 

and during opening it is ignored. With DIP3 = ON during closing it 

stops the gate and after clearing photocells it closes again. During 

opening it stops the gate and after clearing the photocells, it closes.

15

17

Courtesy light output DIP5 = ONlight on for 120 seconds 

(24 Vac Max 10W)

8

9

SAFETY EDGE Input (COSTA). 

18

19

Backup battery input

9

10

Input for closing limit switch

N.C. contact

T1

T2

Motor output 24 Vdc.

9

11

Input for opening limit switch

N.C. contact

J1

ENCODER connector

12

13

Output power only during movement of the gate for photocells. Useful 

for energy saving while gate is still and mandatory in order to use 

feature PHOTOTEST DIP6=ON. It is possible to wire only 2 pairs of 

photocells (max 150mA)

J2

Connector for secondary input of the transformer 24 Vac

6 • PROGRAMMING 

It must be carried out after installing all safety devices, in order to reduce risk of injury.

Preliminary checks:

• Connect control panel to the electricity mains.

• Check that all LEDs are switched off. If photocells are powered through output 12-13 LED DL7, must be switched on.

Programming:

1. N.B. The gate must be closed and the closing limit switch engaged LED DL10 = ON.

2. Hold button 

PRGM

 down until led 

DL2

 begins flashing and then remains steady. 

3. Give a 

1

st

 

START

 command (or remote control command previously stored as in the instructions), the gate opens.

4. While opening is almost completed, give a 

2

nd

 

START

 command, to fix opening slowing down. The gate will continue the travel until the opening limit switch is 

engaged and the led 

DL2

 turns off. After 3 seconds the gate closes automatically.

5. While closing is almost completed, give a 

3

rd

 

START

 command to fix slowing down in closing. The gate will continue the travel until the closing limit switch is 

engaged. After 3 seconds the gate opens automatically.

6. Once reached the desired pedestrian opening, give a 

4

th

 

START

 command, the gate is stopped and this fix the partial pedestrian opening. After 3 seconds the 

gate closes automatically and the programming is now completed.

If within 10 seconds from point 2 the sequence of programming is not started, led 

DL2

 turns off and the procedure is terminated automatically. 

During programming procedure any 

STOP

 command or photocell intervention will cause the termination of programming procedure (The gate stops, the led 

DL2

 

turns off and program is cancelled). It is mandatory to follow strictly the sequence described above.

Adjustment:

• Operating trimmers 

CL PWR - OP PWR 

are for adjusting the torque, in order to make the gate stop as required by regulations and carry out the necessary 

measurements. 

• Exceeding the set torque level will make the anti- crushing feature intervene: while closing the gate reverses the movement until complete opening, during 

opening it reverses the movement for about 10 cm and it stops. Attention! In case of intervention for 3 consecutive times of anti-crushing feature during closing, 

the gate will remain open and the automatic closing (if activated) will be disabled. It is now required a start command closing of the gate.

• Set the length of the pause time using trimmer 

TCA

 (from 1 to 120 seconds with trimmer set on the maximum TCA unable)

Give information to people involved in the use of the gate about operations and commands, safety devices and any danger arising from the use of the automation. 

Fill in the technical installation file and comply with current regulations. 

Summary of Contents for Pixel

Page 1: ...voor 24 Vdc schuifpoorten 24 Vdc Steuerzentrale f r Schiebetore VER V 2011 J1 TCA SW1 CL PWR OP PWR RX433 DL1 DL2 START PRGM INS DEL PED DL3 DL4 DL6 DL7 DL8 DL10 DL11 1 2 3 4 5 6 LED1 LED2 F1 J2 T1 T2...

Page 2: ...etare l operazione PROCEDURA PER LA CANCELLAZIONE DI UN CODICE Mantenere premuto il tasto DEL PED per pi di 5 secondi si accendono i led LED1 e LED2 A questo punto la modalit di cancellazione uguale a...

Page 3: ...ke LED2 turns off and then on while the second push will make LED2 flash 3 times to indicate that radio code has been deleted If something goes wrong the procedure terminates without the 3 flashes of...

Page 4: ...cla del control remoto los leds LED1 y LED2 destellan 3 veces para indicar la cancelaci n del c digo Despu s de la presi n de la tecla en el receptor y despu s de la primera presi n de la tecla del co...

Page 5: ...2 s allument ce moment l la modalit d effacement est identique la modalit d apprentissage la premi re pression de la touche d effacement de la radiocommande les led LED1 e LED2 s teignent et se rallum...

Page 6: ...eringsproces hetzelfde als het opslagproces Druk tweemaal op de op de afstandsbedieningsknop om de radio code te verwijderen De eerste druk zal LED2 uit en vervolgens aan doen gaan terwijl de tweede d...

Page 7: ...N ALLEN CODEN Die Taste DEL PED f r mehr als 10 Sekunden gedr ckt halten Bei Bet tigung der Taste leuchtet LED2 auf Speicherung eines Codes nach 5 Sekunden gehen LED1 und LED2 an L schung eines Codes...

Page 8: ...NOTES...

Page 9: ...azione cancelli S r l se r serve le droit d apporter toutes les modifications qu elle juge bonnes pour am liorer les produits pr sents dans ce manuel Les illustrations et les photographies sont pureme...

Reviews: