DARLEY
SCREENGUARD STAINLESS STEEL MESH SECURITY SYSTEM
20
Code ZOX14861
Use and maintenance manual
Page 8 of 24
3
3
I
I
N
N
S
S
T
T
A
A
L
L
L
L
A
A
T
T
I
I
O
O
N
N
3.1 Installation
Before installing the punching machine, check for any visible damage. If there is any, do not
install the punching machine and do not use it, but contact COMALL service assistance.
Check that the package contains all the components listed in the previous chapter. If any parts
are missing contact COMALL service assistance.
The punching machine must be installed by qualified personnel, placing the bench on a flat,
solid surface (cement or similar).
3.1.1 Preparing the machine
Remove the packaging from the machine and
dispose of it conforming to current legislation.
3.1.2 Compressed air connection
PRELIMINARY OPERATION
To put the machine into service, check that the factory compressed air supply is equipped
with hoses of suitable diameter for the flow required and a stop cock (valve) before the
punching machine. Do not connect up the punching machine at a distance greater than 3
metres from the compressed air supply. Do not connect up the punching machine to the
air supply without a pressure switch, pressure regulator, gauge, and condensation drain.
IT IS OBLIGATORY TO MAKE SURE THE CONNECTIONS ARE CORRECT BEFORE
SUPPLYING THE MACHINE WITH POWER.
CAUTION
Before introducing air into the punching machine circuit, check the oil level in the intake
filter through the glass; if necessary, top up by undoing the relative reservoir.
Check that the air supply is the same as what is stated in the “technical specifications”
table.
Connect the air supply directly to the
control on the punching machine or to
the filter unit according to the layout
shown in the figure.