5.
To refit the vacuum shroud/pipe onto the collar adaptor, hold
the airline swivel joint so that it does not interfere with the
vacuum tube and to support the end of the air motor.
6.
Rotate the body of the air motor to engage the threads of the
collar adaptor and vacuum base. Ensure a minimum of two
full threads are engaged (2 revolutions). Hold the vacuum
shroud/pipe assembly and tighten the lock nut with the
30mm spanner.
3. Zero Adjustment of Routing Bits
SAFETY NOTICE - Always disconnect the air supply to the air router prior to fitting or
adjusting any part of the air router/jig assembly.
Where accurate depth control/adjustment is required, the zero
must be reset on the router assembly whenever the cutting head
is changed, as follows:
1.
Fit the required routing bit as detailed in section 2.
2.
Hold the vacuum shroud/pipe and loosen the locknut with
the 30mm spanner provided.
3.
Stand the router assembly face down on a flat surface and
press the vacuum base firmly against the flat surface.