The remote unit of the Radi
L
ink
®
system has the following connections and indicators:
Front side of the remote unit:
The remote unit uses the same optical connectors as the plug-in card:
•
Connect the DIN connector of the duplex fiber, marked with a green sleeve, to
the Analogue link output of the remote unit.
•
Connect the ST-connector of the duplex fiber, marked with a blue sleeve, to the
Digital link input of the remote unit.
The 3-way Lemo connector is used for two purposes:
•
For charging the internal Lithium battery: use the supplied charger with the 3-way
Lemo plug to charge the internal battery
•
For powering the remote unit from an external source: use the supplied power
cable with 3-way plug for this purpose. Please refer to the specifications of the
voltage range for the external supply.
On the front side 4 indicators are located:
•
Batt Low: will illuminate if the voltage of the internal battery is too low
•
Link Act: will illuminate if the laser links are active
•
Int Batt: will illuminate if the remote unit is running on the internal battery
•
Ext Power: will illuminate if the remote unit is running on external power
A push button (marked with “Power”) is