USB3-FRM20 User’s Manual
22
3.6 Description of Status Functions
“SP0..5 Setup” :
SP0..3 (Sensor Power) voltage (0.9 ~ 4.1V) can be controlled.
“Log Enable” :
Log On/Off
“Data Check” :
If checked, the previous image data (saved image) and the current image
data are compared and the value of the wrong part is displayed on the left
log screen at the bottom.
“H/W CRC”
: H/W
S/W CRC On/Off.
As a method of handling CRC, it is processed in hardware when checked
“CRC Check”
: CRC Check On/Off.
When checked, check Sum 2Bytes data is added at each end of Frame or Line
according to the selection of
“Frame Check”.
“Frame Check”
: Line CRC
FRAME CRC Check Conversion.
(The line can be selected in the Edit Box at the top of Frame Check)
CRC Value
: Shows CRC value when checking CRC.
CRC ERROR
: Shows the number of CRC errors when checking CRC.
CRC OK
: Shows the number of CRC OKs when checking CRC.
“Clear Error Logs” :
Log On/Off
“Frame Comp” :
If checked, the previous image data (saved image) and the current image
data are compared and the wrong value is displayed on the log screen at
the bottom right.