USB3-FRM20 User’s Manual
14
All files specified above are included on the supplied CDROM. In order to run the sample
program normally, API DLL
(USB-FRM20.DLL)
must be in the folder of the executable file, or in the
Windows system folder or the folder designated by the Path environment variable.
The program execution sequence for viewing images is as follows.
①
Device “Open” click
②
Device “Init” click
③
Pixel bit selection from “8, 16, 24, 32, 16bit YUV”
④
Select from Address_Data Bit 8_8, 16_8, 16_16 among sensor initialization file contents
⑤
Read the sensor initialization file saved as “S-Read” and click “Go”
⑥
The video comes out automatically. Check resolution with Get Res.
⑦
Click the “Start/Stop” toggle button to stop the video.
3.1 Description of Image Frame Functions
(1)
“Device Open” button
Start the device on the selected board.
(2)
“Board#” selection
In case of multiple USB3.0 boards, 4 board numbers (0 ~ 3) are assigned.
(3)
“Ver” button
The board's FPGA and Firmware version are shown.
(4)
“D-PHY” toggle
Check when using D-Phy.
(5)
“Virtual Mode” toggle
Select when using MIPI Virtual Mode.
(6)
“Device Init” button
Initialize the image frame function. When the power is first applied, it performed only
once. Select Video Data Mode from 8bit, 16bit, 24bit, 32bit, 16bit YUV.