background image

 

Controlpanel

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
         

 

 

 

 

 

 

 

 

 

 

              Fig. 2

 

 

  1)

 

Display 

      Shows the current DSP preset number. 

  2)

 

Input XLR input 

      The input equipped with 3 pole XLR/ jack combo socket is electronically balanced to accept the   
      (line) signal from any mixing console.

 

  3)

 

DSP mode control 

      Allows you to select a DSP preset. The LT-218BA has 16 presets which are divided into 3 groups. 
      1. 32-80Hz, 32-90Hz, 32-100Hz, 32-125Hz, 32-160Hz. 
      These presets have standard settings for use with most common active speakers. 
      2. Floor, Stage, Max Loud, DJ, Deep, Cinema, Live.  
      These presets are optimized for use with our LT-212A or LT-215A speakers.  
      3. User 1, User 2, User 3, User 4.  
      If you own the optional interface and software, the LT-218BA offers you the ability to edit existing  
      presets or create new presets to meet your own specific requirements. 

  4)

 

Link XLR output

  

      For linking several LT-series speakers.  

  5)

 

LED array 

      

Power 

      Indicates that AC power is connected and the amplifier is turned on. 

      DSP limit 
  

    Indicates that the DSP protection circuitry is limiting the signal, thus preventing digital clipping. 

  

    Soft clip 

  

    Indicates that the analog soft clipping circuit in the poweramp section is active.  

      A soft clipping circuit clips short signal peaks in a way that is not sounding unpleasant to your ears.  
      Although a soft clipping circuit limits your dynamic range, it allows you to operate on higher volume  
      levels. 

      Protect 
      

Indicates an electrical or thermal fault condition in the power amp 

  6)

 

Volume 

      Use to adjust the input volume level for the LT-218BA.

 

  7)

 

RS-485 Termination (only in older units) 

      Allows you to switch the RS-485 termination on or off. The last device in a RS-485 setup should always  
      have a termination resistor connected. If you’re using only one device in a RS-485 setup make sure  
      that the termination switch is pressed in.  

  8)

 

RS-485 control sockets 

      

Allows you to control one or more devices from the LT-series using your computer and the included 

      software. You can connect up to 32 devices. 

Summary of Contents for LT-218BA

Page 1: ...LT 218BA ORDERCODE D3477...

Page 2: ...P Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our c...

Page 3: ...uct Guide Warning Unpacking Instructions Safety instructions Operating Determinations Return Procedure Claims Description Features Overview Control Panel Marani Dig Amp Software Operation Connection C...

Page 4: ...To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Please consider that da...

Page 5: ...ounding frequency ranges instead This way you avoid causing the next piece of equipment in your sound path to overdrive You also preserve valuable dynamic reserve headroom Avoid ground loops Always be...

Page 6: ...ethod to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the...

Page 7: ...RMS which is enough to ensure maximum dynamics as well as a very high sound quality and very low distortion The build in DSP has 16 presets which makes it possible to use the LT series in almost every...

Page 8: ...t AC power is connected and the amplifier is turned on DSP limit Indicates that the DSP protection circuitry is limiting the signal thus preventing digital clipping Soft clip Indicates that the analog...

Page 9: ...es the operation voltage before connecting the unit to mains 11 Powercon AC power link output You can power up another device as long as the maximum power consumption of the device connected does not...

Page 10: ...an be set by double clicking on the entry field just beneath the Gain slider After double clicking a window will open allowing you to set all the filter s parameters by sliders It is also possible to...

Page 11: ...e more less buttons and can range from 1ms up to 480ms The Bypass button allows the user to bypass the compressor with one touch Volume This slider allows you to set the Signal output Level after the...

Page 12: ...nd it will be possible to recall it later by using the Open Folder option Save Preset to Device The Save Preset to Device on the top of the screen allows the user to SAVE an edited setting as preset i...

Page 13: ...ing materials from the LT 218BA Check that all foam and plastic padding is removed Connect all cables Always disconnect from electric mains power supply before cleaning or servicing Damages caused by...

Page 14: ...em This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using un...

Page 15: ...the fuse cover Gently pry up the fuse cover 3 Remove the used fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be...

Page 16: ...1000 Watt RMS in 4 Ohm Damping factor at 100 Hz 2000 in 8 Ohm Input Sensitivity 0 dBu XLR High Out 6dB at 0dB input DSP Marani Dig Amp DSP Freq Response 3 dB 32 Fh Hz Freq Range 10 dB 26 Fh Hz Sensiti...

Page 17: ...2011 Dap Audio...

Reviews: