7
9)
Fuse Holder
Replace the fuse only with a fuse of same specifications (T8A).
10)
Powercon AC power input
This connector is meant for the connection of the supplied main cord. Connect one end of the
power cord to the connector, the other end to the mains, then turn on the power switch
(14)
to
operate the unit.
Note:
Please make sure that the supply voltage matches the operation voltage before connecting
the unit to mains.
11)
Powercon AC power link output
You can power up another device as long as the maximum power consumption of the device
connected does not exceed 1500VA.
12)
Ground Lift switch
When this button is pressed, it separates the signal ground from the chassis ground, enabling you to
eliminate potential ground loops or low-frequency hum.
13)
AC Power Switch
This is the main Power switch. Press to turn the LT-218BA on.
14)
Aux High XLR output
For connecting a mid-high range speaker e.g. LT-212A, LT-215A etc.