background image

 

13 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

Maintenance 

 

The LT-218BA requires almost no maintenance. However, you should keep the unit clean. Disconnect the 
mains power supply, and then wipe the cover with a damp cloth. Do not immerse in liquid.  
Keep connections clean. Disconnect electric power, and then wipe the audio connections with a damp 
cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric power. 
 

Replacing a Fuse 

Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the 
fuse burns out, the product will not function whatsoever. If this happens, follow the directions below to do 
so. 

1.

 Unplug the unit from electric power source. 

2.

 Insert a flat-head screwdriver into a slot in the fuse cover. Gently pry up the fuse cover. 

3.

 Remove the used fuse. If brown or unclear, it is burned out. 

4.

 Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to  

    use a fuse of the same type and specification. See the product specification label for details. 
 
 

Troubleshooting 

 

Dap Audio LT-218BA 

This troubleshooting guide is meant to help solve simple problems.  
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit 
operates properly, do not carry out following steps. 

1.

 If the device does not operate properly, unplug the device. 

2.

 Check the power from the wall, the fuse, all cables etc. 

3.

 If all of the above appears to be O.K., plug the unit in again.

 

4.

 If you are unable to determine the cause of the problem, do not open the device, as this may  

    Damage the unit and the warranty will become void. 

5. 

Return the device to your Dap Audio dealer. 

Summary of Contents for LT-218BA

Page 1: ...LT 218BA ORDERCODE D3477...

Page 2: ...P Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our c...

Page 3: ...uct Guide Warning Unpacking Instructions Safety instructions Operating Determinations Return Procedure Claims Description Features Overview Control Panel Marani Dig Amp Software Operation Connection C...

Page 4: ...To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Please consider that da...

Page 5: ...ounding frequency ranges instead This way you avoid causing the next piece of equipment in your sound path to overdrive You also preserve valuable dynamic reserve headroom Avoid ground loops Always be...

Page 6: ...ethod to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the...

Page 7: ...RMS which is enough to ensure maximum dynamics as well as a very high sound quality and very low distortion The build in DSP has 16 presets which makes it possible to use the LT series in almost every...

Page 8: ...t AC power is connected and the amplifier is turned on DSP limit Indicates that the DSP protection circuitry is limiting the signal thus preventing digital clipping Soft clip Indicates that the analog...

Page 9: ...es the operation voltage before connecting the unit to mains 11 Powercon AC power link output You can power up another device as long as the maximum power consumption of the device connected does not...

Page 10: ...an be set by double clicking on the entry field just beneath the Gain slider After double clicking a window will open allowing you to set all the filter s parameters by sliders It is also possible to...

Page 11: ...e more less buttons and can range from 1ms up to 480ms The Bypass button allows the user to bypass the compressor with one touch Volume This slider allows you to set the Signal output Level after the...

Page 12: ...nd it will be possible to recall it later by using the Open Folder option Save Preset to Device The Save Preset to Device on the top of the screen allows the user to SAVE an edited setting as preset i...

Page 13: ...ing materials from the LT 218BA Check that all foam and plastic padding is removed Connect all cables Always disconnect from electric mains power supply before cleaning or servicing Damages caused by...

Page 14: ...em This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using un...

Page 15: ...the fuse cover Gently pry up the fuse cover 3 Remove the used fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be...

Page 16: ...1000 Watt RMS in 4 Ohm Damping factor at 100 Hz 2000 in 8 Ohm Input Sensitivity 0 dBu XLR High Out 6dB at 0dB input DSP Marani Dig Amp DSP Freq Response 3 dB 32 Fh Hz Freq Range 10 dB 26 Fh Hz Sensiti...

Page 17: ...2011 Dap Audio...

Reviews: