background image

 

WARNING 

 
 
 
 
 

Unpacking Instructions 

Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure 
that all parts are present, and have been received in good condition. Notify the dealer immediately and 
retain packing material for inspection if any parts appear damaged from shipping or the carton itself 
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be 
returned to the factory, it is important that the fixture be returned in the original factory box and packing. 

 
Your shipment includes: 

• DAP LT-218BA 
• IEC cable 
• User manual

 

 
 
 
 
 
 

 

 

SAFETY INSTRUCTIONS 

Every person involved with the installation, operation and maintenance of this system has to: 

-

 

be qualified 

-

 

follow  the instructions of this manual 

 
 
 
 
 
 
 
Before you initial start-up, please make sure that there is no damage caused by transportation. Should 
there be any, consult your dealer and do not use the system. 
 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes written in this manual. 
 
Please consider that damages caused by manual modifications to the system are not subject to 
warranty. 
 
This system contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

IMPORTANT:

 

The manufacturer will not accept liability for any resulting damages caused by the non-
observance of this manual or any unauthorized modification to the system. 

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY  

BEFORE YOUR INITIAL START-UP!

 

 

CAUTION! 

 

Keep this system away from rain and moisture! 

 

CAUTION! Be careful with your operations. 

With a dangerous voltage you can suffer 

a dangerous electric shock when touching the wires!

 

 

Summary of Contents for LT-218BA

Page 1: ...LT 218BA ORDERCODE D3477...

Page 2: ...P Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our c...

Page 3: ...uct Guide Warning Unpacking Instructions Safety instructions Operating Determinations Return Procedure Claims Description Features Overview Control Panel Marani Dig Amp Software Operation Connection C...

Page 4: ...To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Please consider that da...

Page 5: ...ounding frequency ranges instead This way you avoid causing the next piece of equipment in your sound path to overdrive You also preserve valuable dynamic reserve headroom Avoid ground loops Always be...

Page 6: ...ethod to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the...

Page 7: ...RMS which is enough to ensure maximum dynamics as well as a very high sound quality and very low distortion The build in DSP has 16 presets which makes it possible to use the LT series in almost every...

Page 8: ...t AC power is connected and the amplifier is turned on DSP limit Indicates that the DSP protection circuitry is limiting the signal thus preventing digital clipping Soft clip Indicates that the analog...

Page 9: ...es the operation voltage before connecting the unit to mains 11 Powercon AC power link output You can power up another device as long as the maximum power consumption of the device connected does not...

Page 10: ...an be set by double clicking on the entry field just beneath the Gain slider After double clicking a window will open allowing you to set all the filter s parameters by sliders It is also possible to...

Page 11: ...e more less buttons and can range from 1ms up to 480ms The Bypass button allows the user to bypass the compressor with one touch Volume This slider allows you to set the Signal output Level after the...

Page 12: ...nd it will be possible to recall it later by using the Open Folder option Save Preset to Device The Save Preset to Device on the top of the screen allows the user to SAVE an edited setting as preset i...

Page 13: ...ing materials from the LT 218BA Check that all foam and plastic padding is removed Connect all cables Always disconnect from electric mains power supply before cleaning or servicing Damages caused by...

Page 14: ...em This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using un...

Page 15: ...the fuse cover Gently pry up the fuse cover 3 Remove the used fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be...

Page 16: ...1000 Watt RMS in 4 Ohm Damping factor at 100 Hz 2000 in 8 Ohm Input Sensitivity 0 dBu XLR High Out 6dB at 0dB input DSP Marani Dig Amp DSP Freq Response 3 dB 32 Fh Hz Freq Range 10 dB 26 Fh Hz Sensiti...

Page 17: ...2011 Dap Audio...