Dante DLI1971 Installation And Operation Manual Download Page 5

2. 2 Camera parameter

Power supply

Decoder

Built-in

Power supply

DC12V

Cosumption

9W

Rotati on speed

Pan1 ~200 /S

°

°

2. 1 Dome parameter

Operational

Pan rotation

360

°

Moni tor way

Preset/tour/scan/
pattern

Physical

Operation temperature

-10

+50

℃ —

Mount way

Material

Aluminum, iron and carbon alloy, plastic

Setting

Baud rate RS485

2400/4800/9600/19200bps

Communication Protocol

Pelco-D

Pelco-P Factory

ID setting

0-255

Speed

Limitless variable-speedcontrolling

Preset

128

Weight

Tilt rotation

Tilt90

with auto-flip

°,

Environmental humidity

0 75%(no condensation)

2

2.Dom e performance

Tilt1 ~150 /S

°

°

Ceiling mount

Dome performance

Camera Parameters 

            DLI1971 – 10X Color 

Image Sensor 

¼” Sony CCD 

Resolution 

Color 500/570BW TVL 

Effective Pixels 

NTSC 768(H) x 494(V) / PAL 752(H) x 582(V) 

Signal Format 

NTSC/PAL 

Video Output 

1V p-p (sync negative) 

Camera Module 

Samsung 

Focus Auto/Manual 

Aperture F1.8~F3.2 

Optical/Digital Zoom 

10X/10X 

Sync 

Internal / VD-Lock 

AES 

NTSC 1/60~1/120,000 sec. / PAL  1/50~1/120,000 sec. 

S/N Ratio 

>50dB 

Min. Illumination 

0.7LUX F1.8 / 0.02LUX BW F1.8 

IRIS Auto/Manual 

Focus Auto/Manual 

White Balance 

ATW/AWC/Manual 

Gain Normal, 

High, 

OFF 

BLC Low/Middle/High/OFF

 

Summary of Contents for DLI1971

Page 1: ...DLI1971 10X Optical 10X Digital Color Mini PTZ Domes Description 1 3 Mini PTZ Dome Installation and Operations Manual Model Number DLI1971 Day Night 10X Optical Digital Zoom...

Page 2: ...Mini high Speed Dome Operation Manual...

Page 3: ...c operation of menu and keyboard 6 4 5 1 Auto flip 10 4 5 2 Timely auto active action 11 4 5 3 Power up action 11 2 1 Dome parameter 2 2 2 Camera parameter 2 2 3 Dome performance Feature 3 8 4 Rs485 B...

Page 4: ...acking did Damage caused by improper transportation is not within the warranty Do not install it in any other orientation Do not squeezed structure parts which may cause mechanical damage Down cover i...

Page 5: ...otation Tilt90 with auto flip Environmental humidity 0 75 no condensation 2 2 Dome performance Tilt1 150 S Ceiling mount Dome performance Camera Parameters DLI1971 10X Color Image Sensor Sony CCD Reso...

Page 6: ...he data are stored in the inner of camera pan tilt when power off the storage data can t be lose b Built in decoder Integrated and multi protocol includePELCO D PELCO P FACTORY and mainstream protocol...

Page 7: ...ase contact dealer to get necessary information under some conditions there are have some particular requirements and operations 3 1Auto run motion By the menu park time and park action user may set a...

Page 8: ...of camera lens and the position can display on the screen Set and call preset Tour Scan Pattern Lens position display 3 4 Constant temperature Function Inner temperature sensor surveille temperature i...

Page 9: ...in following passages when choosing pictures it means to increase Iris when setting menu it means to enter into the next menu or setting or save after finishing setting when choosing pictures it mean...

Page 10: ...the label to move joystick t choose character after editing Pressing OPEN to save 6 Moving joystick to BACK press OPEN to back to the former menu Press Close to exit Character of label is suitable for...

Page 11: ...ess communication parameter System setting may change the numerical value of initial information 95 preset or transfer 9 preset twice in three seconds to enter the main menu OPEN OPEN System setting 8...

Page 12: ...ngel 45 means tilt angle 95 preset or transfer 9 preset twice in three seconds to enter the main menu magnification display setting DOME LABEL dome label display setting PRESET LABEL preset label or s...

Page 13: ...function user holds the joystick in the down position the camera rotates pan 180 degrees after the camera rotates tilts up to 90 degrees you may directly watch the rear view to surveillance all proces...

Page 14: ...rsor to POWER UP ACTION press OPEN to jump to the following choice tilt up down joystick to choose power up action press OPEN to save run scan run pattern X run tour none action the dome resumes the p...

Page 15: ...esume before production clear all windows and alarm setting Please be cautious to use this function RESTART The dome restart 4 Set clear zone as an example to explain the process Tilt up down joystick...

Page 16: ...trol the dome then all the domes control ed by the system will execute the same action 255 is broadcast address C Debug address only protocol of Factory and PecLo can be set if the dome address is 0 t...

Page 17: ...ay current preset move the cursor to SHOW PRESET press OPEN the screen will display the current preset Clear current preset move the cursor to CLEAR PRESET press OPEN the current preset is cleared Edi...

Page 18: ...SET LEFT LIMIT SET RIGHT LIMIT RUN SCAN CLEAR SCAN EDIT SCAN LABEL Function setting 15 SCAN SCAN SPEED 50 SET LEFT LIMIT SET RIGHT LIMIT RUN SCAN CLEAR SCAN EDIT SCAN LABEL BACK EXIT EDIT SCAN LABEL...

Page 19: ...the cursor to PROGRAM PATTERN press OPEN to set pattern track move the image wantonly and draw the focus The dome has a tour that is no less than 180s a series of park time magnification focus will be...

Page 20: ...55 s Set tour move the cursor to tour dwell 00 00 00 00 press OPEN the first dwell is activated tilt up down joystick to choose preset number press OPEN the cursor jumps to the next dwell press CLOSE...

Page 21: ...ES press OPEN to enter submenu as the left picture shows choose zone number as current zone there choices in the menu aim at current zone set current zone s left limit set current zone s right limit c...

Page 22: ...screws to fasten the base board on the roof As the picture Picture7 1 2 3 Insert three screw in the mini dome into the aperture on the base board then turn 15 degrees in clockwise 4 Connect the power...

Page 23: ...ntle the decoration cover 4 use M2 nut to firm the discreteness of camera on the stator Intallation instruction Picture7 3 1 Picture7 3 2 Picture7 3 3 Picture7 3 4 3 Put one side of connection line wh...

Page 24: ...tion line of the camera in the right position and insert the connector 7 put on decoration cover 8 put on shell Installation instruction Picture7 3 5 Picture7 3 6 Picture7 3 7 Picture7 3 8 5 Using 2 M...

Page 25: ...ET LABEL OFF ZONE LABEL OFF ZOOM LABEL OFF DIRECTION LABEL ON TEMPERATURE LABEL OFF BACK EXIT MOTION AUTO FLIP ON PROPORTION PAN ON PARK TIME 005 PARK ACTION SCAN POWER UP ACTION AUTO FAN ENABLED 40 B...

Page 26: ...mooth Controlling line is bad connection Rs485 loads so many or the distance of communication is much far 1 Connect 120 resistance in the dome pan tilt that is far from the controller 2 Increase distr...

Page 27: ...e jumper on Pin1 pin2 Install the PCB back and the termination resistor is connected as show the picture8 4 3 The connection of 120 temination resistor 24 Factory default setting Connection of120 sett...

Page 28: ...e and connection of Rs485 C Make sure the connections are fully seated D Change Rs485 Bus wires A Secure the connection B Replace Rs485 bus wires C Add termination resistors to the system D Install Rs...

Reviews: