background image

 

 

Arm indicator 

Always on 

Arm status 

Slow flickering 

Settings status/At home status 

Fast flickering 

Alarming status 

 

 

Lights 

3 seconds shiny look 

Home network successfully, and normal standby 

Flicker 

Are registered or not installed SIM card network 

Extinguish 

System failure 

 

 

Power-on for the First Time

 

 

   

  Following the method of installation, install the SIM card of main unit, make wired connection and fit the 

GSM antenna properly in order. Then plug the power adapter.   

At this point, the host of the eight lights flashing cycle, after the host began to detect GSM network, the power 

light flashes until the network is normal, the power light flashes slowly (3 seconds flashes once), the host is 

disarmed ... ... 

      At last, slide the switch of backup battery to [ON] with nippers or a small screwdriver. 

 

 

Factory Reset

 

 

     

First switch off the backup battery and cut off the power supply, press and hold the button [Set] on the top 

of unit,then turn on the power adapter; 

Z1 

Light; 3 seconds after the buzzer "beep" a long sound, lights were 

flashing,  and  finally  release  the  button.  Host  settings  have  all  been  removed,  restoring  the  value  of  a 

successful factory. 

 

Voice Record

 

 

   

  In the status of disarm, press [Set] for 3 

times, the main unit emits a long “beep”, and [Arm] indicator 

flickers (once a second), then recording starts: recording at 30cm away from the main unit, with standard of 

moderate voice; 10 seconds later, recording stops automatically and [Arm] indicator goes out. 

 

 

Enter Setting

 

 

   

  In  the  status  of  disarm,  press  and  hold  [Set];  3  seconds  later,  the 

main unit emits a long “beep”, [Arm] 

indicator flickers and the main unit enters the setting status. 

 

     

In the status of settings, as long as keeping the status of setting ([Arm] indicator flickers), you can program 

different settings repeatedly. During setting, however, if you stop setting operation for over 30 seconds, the 

main unit will exit from setting mode automatically and return to the status of disarm. 

 

 

Exit Setting

 

 

     

After setting is finished, all the indicators of the defence zones is off but only [Arm] indicator flickers; press 

[Set] for 3 seconds,the main unit exits from setting. [Arm] indicator goes off, the main unit returns to the status 

of disarm. 

 

Summary of Contents for YA-300-GSM

Page 1: ...well as residential communities 2 Function Introduction 4 wired and 6 wireless defence zones Can preset and store 6 voice phones and 3 message phones Remote two way intercom Built in intercom speaker...

Page 2: ...rm On defence zone 5 wired Valid Valid 24 hours Fire alarm On defence zone 6 wired Valid Valid 24 hours Gas alarm On Remote control emergency key Valid Valid 24 hours Help alarm Programming password 8...

Page 3: ...ion Step 2 Fit the GSM card into the card socket properly Step 3 Push the card socket as close direction until it is fit firmly 6 Main Unit Settings Prompt Message Function Operation Instructions Note...

Page 4: ...eep a long sound lights were flashing and finally release the button Host settings have all been removed restoring the value of a successful factory Voice Record In the status of disarm press Set for...

Page 5: ...l code pairing status press Set once again and the indicator of defence zone 1 goes on Prompt trigger detector then take a sensor required for code pairing and trigger an alarm to emit a wireless sign...

Page 6: ...eration Instructions Notes Enter Programming Enter password Long beep Exit Settings Hang up directly Short Beep Operation Password 30 new password modified Factory default 1234 Programming Password 31...

Page 7: ...amming password into the new password 0000 SMS Command 8888310000 Operation Password after dialing the SIM card number by mobile phone or fixed phone if you enter the operation password factory defaul...

Page 8: ...t the address codes of message receiving numbers from the first group the third group Set Number Delete number Illustration X indicates the set message receiving phone number set 13811111111 to be the...

Page 9: ...y B arm at home stay at home 0 indicates invalid no alarm 1 indicates valid enable alarm Illustration A indicates the number of defence zone B indicates arm at home is valid invalid set the defence zo...

Page 10: ...thod 33 22 45 SMS Command 8888332245 2 Timely Disarm In setup status use keypad to input 36 38 then input the hour AA and minute BB of the time you want to set to disarm and finally input to confirm Y...

Page 11: ...sensors of alerters are always working when the sensor is triggered by door fire gas leak etc the alarm system will sound the alarm After you have done these operations the indicator of Arm on the ma...

Page 12: ...conds 5 key Open 1st home appliance Open relay 6 key Close 1st home appliance Close relay 7 key Open 2nd home appliance 8 key Close 2nd home appliance 9 key Open mini siren or wireless siren If need t...

Page 13: ...rm unit and make a alarm Pair the Siren Wireless siren can only accept the alarm unit signal control after paired Pairing method According to the wireless siren manual make the siren stay the code pai...

Page 14: ...Is the PIN code of SIM card set Cancel it Power indicator always flickering Is the network signal strong enough Change place The signal of Unicom card is weaker than that of China Mobile Alarm failur...

Page 15: ...approval and consent of relevant authorities please do not set 999 110 or the alarm phone number of police station for this main unit 10 Standard Package Main Panel 1pcs Wireless Infrared Detector 1p...