Built in NI-HI rechargeable battery is available to provide power supply nearly 5hours automatically after
power off;
AC and DC dual use are available for 24-hours-a-day normal guard;
Main unit anti-tamper and low-voltage detecting function.
3 Technical Parameter
4 Factory Default
defence zone
Arm
At
Home
Type
Alarm
Conditions
Siren
defence zone 1
Valid
Real-time
Door lock alarm
On
defence zone 2
Valid
Real-time
Hall alarm
On
defence zone 3 (wired)
Valid
Valid
Real-time
Window alarm
On
defence zone 4 (wired)
Valid
Valid
Real-time
Balcony alarm
On
defence zone 5 (wired)
Valid
Valid
24 hours
Fire alarm
On
defence zone 6 (wired)
Valid
Valid
24 hours
Gas alarm
On
Remote control emergency key
Valid
Valid
24 hours
Help alarm
Programming password:
8888
Remote Control:
Enabled
Operation Password:
1234
Ringing Times:
Once
Siren Duration:
180 seconds
Warning Siren:
Disabled
5 Installation
Main Unit Installation
Be careful to keep it away from large metal objects or household appliances which may cause high frequency
interference, as well as barriers such as reinforced concrete walls and fire doors.
Input Voltage:
DC9V~12V
Standby Current:
<55mA
Alarm Current:
<450mA
Wireless Frequency:
315/433.92
MHz, 2262/4.7MΩ
GSM Frequency:
900/1800/1900MHz
Backup Battery:
NI-HI AAA*6 DC7.4V
Alarm Loudness:
110dB