P
I
02 9604 1226 E
I
|
danielaappliances.com.au
PA G E 1 1
INSTALLATION -
GAS CHECKS AND BURNER ADJUSTMENTS
IMPORTANT: Set appliance operating pressure to that indicated on appliance data plate.
The test point is located on the appliance regulator (or adaptor for LPG) .
PRESSURE ADJUSTMENTS
•
the rear of the appliance and place the hose of the Manometer onto it. Turn the gas on to
the appliance and light the Wok Burner and Small Burner at maximum setting. Check the
pressure and adjust at the regulator if necessary to the settings in the table on the last page
or on the Data plate.
•
For Propane Gas, adjust at the regulator on the gas supply cylinder – Turn regulator
adjusting screw clockwise increase pressure whilst anti-clockwise decrease pressure. Refit
the test point sealing screw when finished. Check installation for correct operation.
LOW FLAME SETTING
•
Check the low flame setting for each hob burner with the control engaged in the minimum
position. Turn the control until it engages in the minimum position and remove the control
knob. Insert a screwdriver in the adjusting screw (located next to the gascock shaft). To
increase the flame, turn the adjusting screw anti-clockwise. To decrease the flame, turn the
adjusting screw clockwise. Adjust for a minimum, stable and clear flame.
N.B. Ensure that the minimum flame will not be extinguished by air draughts.
IGNITER OPERATION
•
Check that the igniter for each burner successfully ignites the gas and that the burner
remains alight.
•
If an igniter fails to work or a burner fails to remain alight, first remove the electrical supply
plug from the electrical power outlet (GPO), and then check that all the electrical connections
are clean, dry and in place. Also check burner to ensure ports are not blocked or dirty.
•
If the hotplate fails to operate correctly, contact Daniela Appliances or their appropriate
agent for service.