background image

Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electronic components. We specialize in providing state-of-the-art technology and solutions
that excel in the harsh operating conditions of the mobile off-highway market. Building on
our extensive applications expertise, we work closely with our customers to ensure
exceptional performance for a broad range of off-highway vehicles.

We help OEMs around the world speed up system development, reduce costs and bring
vehicles to market faster.

Danfoss – Your Strongest Partner in Mobile Hydraulics.
Go to www.powersolutions.danfoss.com for further product information.

Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide support
for our customers, ensuring the best possible solutions for outstanding performance. And
with an extensive network of Global Service Partners, we also provide comprehensive global
service for all of our components.

Please contact the Danfoss Power Solution representative nearest you.

Local address:

Danfoss 

Power Solutions GmbH & Co. OHG

Krokamp 35

D-24539 Neumünster, Germany

Phone: +49 4321 871 0

Danfoss 

Power Solutions ApS

Nordborgvej 81

DK-6430 Nordborg, Denmark

Phone: +45 7488 2222

Danfoss 

Power Solutions (US) Company

2800 East 13th Street

Ames, IA 50010, USA

Phone: +1 515 239 6000

Danfoss 

Power Solutions Trading

(Shanghai) Co., Ltd.

Building #22, No. 1000 Jin Hai Rd

Jin Qiao, Pudong New District

Shanghai, China 201206

Phone: +86 21 3418 5200

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products

already on order provided that such alterations can be made without changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

©

 Danfoss | March 2016

L1426375 | BC00000241en-US0203

Products we offer:

Bent Axis Motors

Closed Circuit Axial Piston

Pumps and Motors

Displays

Electrohydraulic Power

Steering

Electrohydraulics

Hydraulic Power Steering

Integrated Systems

Joysticks and Control

Handles

Microcontrollers and

Software

Open Circuit Axial Piston

Pumps

Orbital Motors

PLUS+1

®

 GUIDE

Proportional Valves

Sensors

Steering

Transit Mixer Drives

Comatrol

www.comatrol.com
Schwarzmüller-Inverter

www.schwarzmueller-

inverter.com
Turolla 

www.turollaocg.com
Hydro-Gear

www.hydro-gear.com
Daikin-Sauer-Danfoss

www.daikin-sauer-danfoss.com 

Summary of Contents for WS 403

Page 1: ...Technical Information Telematics Solutions WS 403 Remote Solution powersolutions danfoss com...

Page 2: ...sions Date Changed Rev March 2016 Engineering Tomorrow 0203 January 2015 Updates BB November 2014 Review BA June 2014 First edition AA Technical Information WS 403 Remote Solution 2 Danfoss March 2016...

Page 3: ...perty damage 12 FCC notice 13 Warranty and liability 14 Device functions Wireless solution 15 GPS 15 GPRS EDGE 3G HSDPA 15 Operating modes 15 Real time mode 15 Data logging File transfer mode 15 WS 40...

Page 4: ...s 25 Additional features 25 Protocols 26 Troubleshooting Tests EMC tests 28 Electrical loads 28 Temperature climate tests 28 Shock vibration tests 29 Packaging and transport European Union Technical I...

Page 5: ...ended for qualified personnel and electricians with advanced knowledge in electrical engineering and fieldbus systems allowing them to estimate the risks and hazards of operating the device and to int...

Page 6: ...wed in the figure below 1 Power CAN connector 2 GSM 3G connector 3 GPS connector 4 Mounting holes 5 Aluminum enclosure 6 GPS LED 7 GSM 3G LED 8 ON LED 9 CAN LED 10 Front label 11 Enclosure screws 12 T...

Page 7: ...controls are installed has the full responsibility for all consequences that may occur Danfoss has no responsibility for any consequences direct or indirect caused by failures or malfunctions Danfoss...

Page 8: ...on request You can find this name extension on the type label on the WS unit The tables below list the part numbers of the devices covered in this manual Device Descriptions Part number WS403 CONTROL...

Page 9: ...support The most recent driver firmware tools and documentation versions are available for download from the website For further information see our website http powersolutions danfoss com solutions...

Page 10: ...following two conditions 1 this device may not cause harmful interference 2 2 this device must accept any interference received including interference that may cause undesired operation Contains tran...

Page 11: ...o check and comply with regional directives and requirements Safety advice General Danger due to possibly deficient data transmission WS unit operates using radio signals and cellular networks and is...

Page 12: ...tter Electronic equipment Danger of interference caused by RF energy WS unit receives and transmits radio frequency energy while switched on Interference may occur if it is used close to TV sets radio...

Page 13: ...itions the separation distance between the antenna s and all persons is at least 20 cm approx 8 inches The antenna s must further not be co located or operated in conjunction with any antenna or trans...

Page 14: ...intenance This also applies if the customer itself or third parties without our approval modify the components of our products e g devices elements or additional hardware facilities programs or progra...

Page 15: ...er Operating modes WS devices can be operated in the following modes Real time mode Data Logging File Transfer mode Real time mode CAN messages are received by the device and sent via the Danfoss Web...

Page 16: ...to 1 Mbit s Support for CAN FD is not available The CAN interface is operational only when power supply is energized Mobile connection The WS unit is equipped with an HSPA UMTS GSM GPRS EDGE module I...

Page 17: ...nnected via a SMA connector at the same time the active antenna is supplied through this connector 3 axis accelerometer The device has a 3 axis accelerometer that can measure continuous acceleration v...

Page 18: ...le by unscrewing the housing The micro SD card is connected via SDIO to the MCU There are both micro SD and microSDHC cards Technical Information WS 403 Remote Solution WS 403 functionalities 18 Danfo...

Page 19: ...local geographic horizon and has full view of the sky above If you are using separate GSM 3G and GPS antennas mounting them at least 2 meters away from each other will also help to improve the GPS pe...

Page 20: ...onnector SMA female front view Pin Designation Description P301 766 2 1 1 Signal GSM 3G 2 Ground Shield housing Technical Information WS 403 Remote Solution Connectors 20 Danfoss March 2016 L1426375 B...

Page 21: ...onstantly on CANopen NMT status operational blinking CANopen NMT status preoperational single flash CANopen NMT status stopped red off No CAN data receiving sending constantly on CAN error i e bus off...

Page 22: ...erver red off No TCP IP data over the air receiving sending constantly on Fatal GSM 3G error i e no SIM card inserted flashing irregularly TCP IP data over the air receiving sending first green then r...

Page 23: ...same time and synchronously flashing red so all LEDs blinking orange the device is in firmware update mode Do not switch the device off Technical Information WS 403 Remote Solution Indicator elements...

Page 24: ...d s 4x CAN ON 120 5 126 42 1 P301 767 J1 CAN power connector 5 pin M12 J2 GSM 3G connector FME J3 GPS connector SMA Technical Information WS 403 Remote Solution Technical drawings 24 Danfoss March 201...

Page 25: ...mA Memory Program Configuration Data 1 MB 32 MB 512 kB Interface Protocols Certifications Device type WS403 CAN bus Network 1 ISO 11898 2 High Speed 2 0A B GSM GPRS EDGE class 10 850 900 1800 1900 HHz...

Page 26: ...Protocols Device type WS403 Layer 2 CANopen Technical Information WS 403 Remote Solution WS 403 technical data 26 Danfoss March 2016 L1426375 BC00000241en US0203...

Page 27: ...correctly and activated Direct communication with the device is not possible Check if the CAN filter settings in the WS Configurator are selected correctly In the Communication Settings Options Settin...

Page 28: ...8 30 A m Conducted Emissions CISPR 16 2 Class B Radiated Emissions CISPR 16 2 Class B Electromagnetic field immunity test ISO11452 4 60mA 20 80 MHz 30 V m 80 1000 MHz Electrical transient immunity te...

Page 29: ...5mm 22 500 Hz 5g Test time 3 hours per axis Shock EN 60 068 2 27 Test Ea 15g 11ms half sine 500 shocks each axis direction Shock EN 60 068 2 29 Test Eb 30g 11ms half sine 3 shocks each axis direction...

Page 30: ...ectors are not plugged in Do not immerse the device in water or other liquids Make sure that WS devices are stored and transported at a temperature between 40 C and 85 C or 40 F and 185 F respectively...

Page 31: ...ke the device to a collection point for waste electrical and electronic equipment for correct disposal Alternatively you can return the device to your dealer for proper disposal Batteries and recharge...

Page 32: ...K 6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 N...

Reviews: