In this chapter, you will find important information on how to avoid life-threatening situations and
injuries and how to prevent product damage.

General information

These instructions are part of the device.

They contain text and illustrations for the correct handling of the module and must be read before
installation or use.

Before deploying the device described in this document, read the entire manual including all safety
information.

Non-observance of the notes, operation that is not in accordance with use as prescribed below, wrong
installation or handling can result in serious harm concerning the safety of people and plant.

Keep this manual for future use and make all information available to anyone deploying the device, even
after installation.

Tampering with the device can lead to considerable risks for the safety of people and plant. It is not
permitted and leads to an exclusion of any liability and warranty claims.

The device must be installed, connected and put into operation by a qualified electrician.

In the event of malfunctions or uncertainties, please contact the manufacturer.

This device is designed to be used in systems which must be checked for conformity with legal
requirements prior to placing into operation. The integrator of this device is responsible to check and
comply with regional directives and requirements.

Safety advice

General

Danger due to possibly deficient data transmission.

WS unit operates using radio signals and cellular networks and is not authorized for use in safety-related
applications.

Deficient network coverage, failure or malfunction of the device may lead to deficient data transmission.
Because of this, connection cannot be guaranteed at all times under all conditions.

Do not operate the device in machines and applications where life depends on the proper operation
of this piece of equipment.

Never rely solely upon any wireless device for essential communications.

Health care

Danger of interference caused by RF energy.

Medical equipment may be sensitive to RF energy.

When in a hospital or other health care facility, observe the restrictions on the use of cellular
communication equipment.

Switch WS unit off, if instructed to do so by the guidelines posted in sensitive areas.

The operation of cardiac pacemakers, other implanted medical device and hearing aids can be affected
by interference from WS unit's antennas placed close to the device.

If in doubt about potential danger, contact a physician or the manufacturer of the implanted medical
device to verify that it is properly shielded.

Pacemaker patients are advised to keep WS unit and its antennas away from the pacemaker while it is
on.

Technical Information

WS 403 Remote Solution

Safety information

 

©

 Danfoss | March 2016

L1426375 | BC00000241en-US0203 | 11

Summary of Contents for WS 403

Page 1: ...Technical Information Telematics Solutions WS 403 Remote Solution powersolutions danfoss com...

Page 2: ...sions Date Changed Rev March 2016 Engineering Tomorrow 0203 January 2015 Updates BB November 2014 Review BA June 2014 First edition AA Technical Information WS 403 Remote Solution 2 Danfoss March 2016...

Page 3: ...perty damage 12 FCC notice 13 Warranty and liability 14 Device functions Wireless solution 15 GPS 15 GPRS EDGE 3G HSDPA 15 Operating modes 15 Real time mode 15 Data logging File transfer mode 15 WS 40...

Page 4: ...s 25 Additional features 25 Protocols 26 Troubleshooting Tests EMC tests 28 Electrical loads 28 Temperature climate tests 28 Shock vibration tests 29 Packaging and transport European Union Technical I...

Page 5: ...ended for qualified personnel and electricians with advanced knowledge in electrical engineering and fieldbus systems allowing them to estimate the risks and hazards of operating the device and to int...

Page 6: ...wed in the figure below 1 Power CAN connector 2 GSM 3G connector 3 GPS connector 4 Mounting holes 5 Aluminum enclosure 6 GPS LED 7 GSM 3G LED 8 ON LED 9 CAN LED 10 Front label 11 Enclosure screws 12 T...

Page 7: ...controls are installed has the full responsibility for all consequences that may occur Danfoss has no responsibility for any consequences direct or indirect caused by failures or malfunctions Danfoss...

Page 8: ...on request You can find this name extension on the type label on the WS unit The tables below list the part numbers of the devices covered in this manual Device Descriptions Part number WS403 CONTROL...

Page 9: ...support The most recent driver firmware tools and documentation versions are available for download from the website For further information see our website http powersolutions danfoss com solutions...

Page 10: ...following two conditions 1 this device may not cause harmful interference 2 2 this device must accept any interference received including interference that may cause undesired operation Contains tran...

Page 11: ...o check and comply with regional directives and requirements Safety advice General Danger due to possibly deficient data transmission WS unit operates using radio signals and cellular networks and is...

Page 12: ...tter Electronic equipment Danger of interference caused by RF energy WS unit receives and transmits radio frequency energy while switched on Interference may occur if it is used close to TV sets radio...

Page 13: ...itions the separation distance between the antenna s and all persons is at least 20 cm approx 8 inches The antenna s must further not be co located or operated in conjunction with any antenna or trans...

Page 14: ...intenance This also applies if the customer itself or third parties without our approval modify the components of our products e g devices elements or additional hardware facilities programs or progra...

Page 15: ...er Operating modes WS devices can be operated in the following modes Real time mode Data Logging File Transfer mode Real time mode CAN messages are received by the device and sent via the Danfoss Web...

Page 16: ...to 1 Mbit s Support for CAN FD is not available The CAN interface is operational only when power supply is energized Mobile connection The WS unit is equipped with an HSPA UMTS GSM GPRS EDGE module I...

Page 17: ...nnected via a SMA connector at the same time the active antenna is supplied through this connector 3 axis accelerometer The device has a 3 axis accelerometer that can measure continuous acceleration v...

Page 18: ...le by unscrewing the housing The micro SD card is connected via SDIO to the MCU There are both micro SD and microSDHC cards Technical Information WS 403 Remote Solution WS 403 functionalities 18 Danfo...

Page 19: ...local geographic horizon and has full view of the sky above If you are using separate GSM 3G and GPS antennas mounting them at least 2 meters away from each other will also help to improve the GPS pe...

Page 20: ...onnector SMA female front view Pin Designation Description P301 766 2 1 1 Signal GSM 3G 2 Ground Shield housing Technical Information WS 403 Remote Solution Connectors 20 Danfoss March 2016 L1426375 B...

Page 21: ...onstantly on CANopen NMT status operational blinking CANopen NMT status preoperational single flash CANopen NMT status stopped red off No CAN data receiving sending constantly on CAN error i e bus off...

Page 22: ...erver red off No TCP IP data over the air receiving sending constantly on Fatal GSM 3G error i e no SIM card inserted flashing irregularly TCP IP data over the air receiving sending first green then r...

Page 23: ...same time and synchronously flashing red so all LEDs blinking orange the device is in firmware update mode Do not switch the device off Technical Information WS 403 Remote Solution Indicator elements...

Page 24: ...d s 4x CAN ON 120 5 126 42 1 P301 767 J1 CAN power connector 5 pin M12 J2 GSM 3G connector FME J3 GPS connector SMA Technical Information WS 403 Remote Solution Technical drawings 24 Danfoss March 201...

Page 25: ...mA Memory Program Configuration Data 1 MB 32 MB 512 kB Interface Protocols Certifications Device type WS403 CAN bus Network 1 ISO 11898 2 High Speed 2 0A B GSM GPRS EDGE class 10 850 900 1800 1900 HHz...

Page 26: ...Protocols Device type WS403 Layer 2 CANopen Technical Information WS 403 Remote Solution WS 403 technical data 26 Danfoss March 2016 L1426375 BC00000241en US0203...

Page 27: ...correctly and activated Direct communication with the device is not possible Check if the CAN filter settings in the WS Configurator are selected correctly In the Communication Settings Options Settin...

Page 28: ...8 30 A m Conducted Emissions CISPR 16 2 Class B Radiated Emissions CISPR 16 2 Class B Electromagnetic field immunity test ISO11452 4 60mA 20 80 MHz 30 V m 80 1000 MHz Electrical transient immunity te...

Page 29: ...5mm 22 500 Hz 5g Test time 3 hours per axis Shock EN 60 068 2 27 Test Ea 15g 11ms half sine 500 shocks each axis direction Shock EN 60 068 2 29 Test Eb 30g 11ms half sine 3 shocks each axis direction...

Page 30: ...ectors are not plugged in Do not immerse the device in water or other liquids Make sure that WS devices are stored and transported at a temperature between 40 C and 85 C or 40 F and 185 F respectively...

Page 31: ...ke the device to a collection point for waste electrical and electronic equipment for correct disposal Alternatively you can return the device to your dealer for proper disposal Batteries and recharge...

Page 32: ...K 6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 N...

Reviews: