background image

MI.58.E3.02 - VLT is a registered Danfoss trademark

2

Relay unit for pump controller VLA 31

Relay unit for pump contr

oller VLA 31

This relay module for VLA 31 is  avalilable in IP20.

The connecting drawing on page 2 must be followed.

The DC voltage supply for VLA 31 has been changed

from 15 V to 24 V, and 6 light emitting diodes have

been mounted on the frontplate of the relay module:

The LED “POWER” lights up, if the supply voltage

is OK and the fuse protecting the DC voltage

supply is intact.

The LED’s 1-5 light up, when the relays of the

corresponding numbers are energized.

New code numbers

Relay module

190Z4140

Wall mounting brackets

175U0599

Fuse for voltage supply (0.2 A)

984B3002

Fuse for relay protection (5 A)

984B3069

Technical data

Supply voltage

100, 115, 220, 240 V, 50/60 Hz

Voltage supply for VLA 31

24 V  

---

Number of relay contacts

5

Max. contact load

250 V ~ , 2 A

Ambient temperature

operation

-20°C to +40°C

Storage

-40°C to +70°C

RFI suppression

EN55014

Enclosure

IP10 (VBG 4)

Between supply and DC output

3.6 kV ~ for 1 min

Test voltage

Across relay contacts

2.5 kV ~ for 1 min

Between terminals and chassis

2.5 kV ~ for 1 min

Weight

1.1 kg

Dimensions

Quick Action

↓↓↓↓↓