Mechanical dimensions
Frame
size
A2
A3
A5
B1
B2
C1
C2
1.1-3 kW
(200-240 V)
2.2-4.0 kW
(380-480 V)
3.0-3.7 kW
(200-240 V)
5.5-7.5 kW
(380-480 V)
1.1-3.7
kW
(200-240
V)
1.1-7.5
kW
(380-480
V)
5.5-11 kW
(200-240
V)
11-18.5
kW
(380-480
V)
15 kW
(200-240
V)
22-30 kW
(380-480
V)
18.5-22
kW
(200-240
V)
37-55 kW
(380-480
V)
30-45 kW
(200-240
V)
75-90 kW
(380-480
V)
IP
NEMA
20
Chassis
21
Type 1
20
Chassis
21
Type 1
55/66
Type 12
21/ 55/66
Type 1/
Type 12
21/55/66
Type 1/
Type 12
21/55/66
Type 1/
Type 12
21/55/66
Type 1/
Type 12
Height
Height of
back plate
A 268 mm
375
mm
268 mm
375
mm
420 mm
480 mm
650 mm
680 mm
770 mm
Height with
de-cou-
pling plate
A
373.79
-
373.79
-
-
-
-
Distance
between
mounting
holes
a
257 mm
350
mm
257 mm
350
mm
402 mm
454 mm
624 mm
648 mm
739 mm
Width
Width of
back plate
B
90 mm 90 mm 130 mm
130
mm
242 mm
242 mm
242 mm
308 mm
370 mm
Width of
back plate
with one C
option
B
130 mm
130
mm
170 mm
170
mm
242 mm
242 mm
242 mm
308 mm
370 mm
Width of
back plate
with two C
options
B
150 mm
150
mm
190 mm
190
mm
242 mm
242 mm
242 mm
308 mm
370 mm
Distance
between
mounting
holes
b
70 mm 70 mm 110 mm
110
mm
215 mm
210 mm
210 mm
272 mm
334 mm
Depth
Depth
without op-
tion A/B
C 205 mm
205
mm
205 mm
205
mm
195 mm
260 mm
260 mm
310 mm
335 mm
With option
A/B
C 220 mm
220
mm
220 mm
220
mm
195 mm
260 mm
260 mm
310 mm
335 mm
Without
option A/B
D
207
mm
207
mm
-
-
-
-
-
With option
A/B
D
222
mm
222
mm
-
-
-
-
-
Screw
holes
c
8.0 mm
8.0
mm
8.0 mm
8.0
mm
8.25 mm
12 mm
12 mm
12 mm
12 mm
d
ø11 mm
ø11
mm
ø11 mm
ø11
mm
ø12 mm
ø19 mm
ø19 mm
ø19 mm
ø19 mm
e ø5.5 mm ø5.5
mm
ø5.5 mm ø5.5
mm
ø6.5 mm
ø9 mm
ø9 mm
ø9.8 mm
ø9.8 mm
f
9 mm
9 mm
9 mm
9 mm
9 mm
9 mm
9 mm
17.6 mm
18 mm
Max
weight
4.9 kg
5.3 kg
6.6 kg
7.0 kg 13.5/14.2
kg
23 kg
27 kg
43 kg
61 kg
VLT
®
HVAC Drive Design Guide
3. VLT HVAC Selection
MG.11.B2.02 - VLT
®
is a registered Danfoss trademark
67
3