background image

15-01

Running

 Hours

15-02

kWh

 Counter

15-03

Power

 Up's

15-04

Over

 Temp's

15-05

Over

 Volt's

15-06

Reset

 kWh

 Counter

15-07

Reset

 Running

 Hours

 Counter

15-3*

Alarm

 Log

15-30

Alarm

 Log:

 Error

 Code

15-31

InternalFaultReason

15-4*

Drive

 Identification

15-40

FC

 Type

15-41

Power

 Section

15-42

Voltage

15-43

Software

 Version

15-44

Ordered

 TypeCode

15-46

Drive

 Ordering

 No

15-47

Power

 Card

 Ordering

 No

15-48

LCP

 Id

 No

15-49

SW

 ID

 Control

 Card

15-50

SW

 ID

 Power

 Card

15-51

Drive

 Serial

 Number

15-53

Power

 Card

 Serial

 Number

15-9*

Parameter

 Info

15-92

Defined

 Parameters

15-97

Application

 Type

15-98

Drive

 Identification

16-**

Data

 Readouts

16-0*

General

 Status

16-00

Control

 Word

16-01

Reference

 [Unit]

16-02

Reference

 [%]

16-03

Status

 Word

16-05

Main

 Actual

 Value

 [%]

16-09

Custom

 Readout

16-1*

Motor

 Status

16-10

Power

 [kW]

16-11

Power

 [hp]

16-12

Motor

 Voltage

16-13

Frequency

16-14

Motor

 current

16-15

Frequency

 [%]

16-18

Motor

 Thermal

16-3*

Drive

 Status

16-30

DC

 Link

 Voltage

16-34

Heatsink

 Temp.

16-35

Inverter

 Thermal

16-36

Inv.

 Nom.

 Current

16-37

Inv.

 Max.

 Current

16-38

SL

 Controller

 State

16-5*

Ref.

 &

 Feedb.

16-50

External

 Reference

16-52

Feedback[Unit]

16-6*

Inputs

 &

 Outputs

16-60

Digital

 Input

16-61

Terminal

 53

 Setting

16-62

Analog

 Input

 AI53

16-63

Terminal

 54

 Setting

16-64

Analog

 Input

 AI54

16-65

Analog

 Output

 AO42

 [mA]

16-66

Digital

 Output

16-67

Pulse

 Input

 #29

 [Hz]

16-71

Relay

 Output

 [bin]

16-72

Counter

 A

16-73

Counter

 B

16-79

Analog

 Output

 AO45

16-8*

Fieldbus

 &

 FC

 Port

16-86

FC

 Port

 REF

 1

16-9*

Diagnosis

 Readouts

16-90

Alarm

 Word

16-91

Alarm

 Word

 2

16-92

Warning

 Word

16-93

Warning

 Word

 2

16-94

Ext.

 Status

 Word

16-95

Ext.

 Status

 Word

 2

18-**

Info

 &

 Readouts

18-1*

Fire

 Mode

 Log

18-10

FireMode

 Log:Event

20-**

Drive

 Closed

 Loop

20-0*

Feedback

20-00

Feedback

 1

 Source

20-01

Feedback

 1

 Conversion

20-8*

PI

 Basic

 Settings

20-81

PI

 Normal/

 Inverse

 Control

20-83

PI

 Start

 Speed

 [Hz]

20-84

On

 Reference

 Bandwidth

20-9*

PI

 Controller

20-91

PI

 Anti

 Windup

20-93

PI

 Proportional

 Gain

20-94

PI

 Integral

 Time

20-97

PI

 Feed

 Forward

 Factor

22-**

Appl.

 Functions

22-4*

Sleep

 Mode

22-40

Minimum

 Run

 Time

22-41

Minimum

 Sleep

 Time

22-43

Wake-Up

 Speed

 [Hz]

22-44

Wake-Up

 Ref./FB

 Diff

22-45

Setpoint

 Boost

22-46

Maximum

 Boost

 Time

22-47

Sleep

 Speed

 [Hz]

22-6*

Broken

 Belt

 Detection

22-60

Broken

 Belt

 Function

22-61

Broken

 Belt

 Torque

22-62

Broken

 Belt

 Delay

24-**

Appl.

 Functions

 2

24-0*

Fire

 Mode

24-00

FM

 Function

24-05

FM

 Preset

 Reference

24-09

FM

 Alarm

 Handling

24-1*

Drive

 Bypass

24-10

Drive

 Bypass

 Function

24-11

Drive

 Bypass

 Delay

 Time

25-**

Cascade

 Controller

25-0*

System

 Settings

25-00

Cascade

 Controller

25-04

Pump

 Cycling

25-05

Fixed

 Lead

 Pump

25-06

Number

 of

 Pumps

25-2*

Bandwidth

 Settings

25-20

Staging

 Bandwidth

25-21

Override

 Bandwidth

25-22

Fixed

 Speed

 Bandwidth

25-23

SBW

 Staging

 Delay

25-24

SBW

 Destaging

 Delay

25-25

OBW

 Time

25-27

Stage

 Function

25-28

Stage

 Function

 Time

25-29

Destage

 Function

25-30

Destage

 Function

 Time

25-4*

Staging

 Settings

25-42

Staging

 Threshold

25-43

Destaging

 Threshold

25-45

Staging

 Speed

 [Hz]

25-47

Destaging

 Speed

 [Hz]

25-5*

Alternation

 Settings

25-50

Lead

 Pump

 Alternation

25-51

Alternation

 Event

25-52

Alternation

 Time

 Interval

25-53

Alternation

 Timer

 Value

25-55

Alternate

 if

 Load

 <=

 50%

25-56

Staging

 Mode

 at

 Alternation

25-57

Relays

 per

 Pump

25-58

Run

 Next

 Pump

 Delay

25-59

Run

 on

 Mains

 Delay

25-8*

Status

25-80

Cascade

 Status

25-81

Pump

 Status

25-84

Pump

 ON

 Time

25-9*

Service

25-90

Pump

 Interlock

38-**

Debug

 only

 -

 see

 PNU

 1429

 (service-

code)

 also

38-0*

All

 debug

 parameters

38-00

TestMonitorMode

38-01

Version

 And

 Stack

38-06

LCPEdit

 Set-up

38-07

EEPROMDdataVers

38-08

PowerDataVariantID

38-09

AMA

 Retry

38-10

DAC

 selection

38-12

DAC

 scale

38-20

MOC_TestUS16

38-21

MOC_TestS16

38-23

TestMocFunctions

38-24

DC

 Link

 Power

 Measurement

38-25

CheckSum

38-30

Analog

 Input

 53

 (%)

38-31

Analog

 Input

 54

 (%)

38-32

Input

 Reference

 1

38-33

Input

 Reference

 2

38-34

Input

 Reference

 Setting

38-35

Feedback

 (%)

38-36

Fault

 Code

38-37

Control

 Word

38-38

ResetCountersControl

38-39

Active

 Setup

 For

 BACnet

38-40

Name

 Of

 Analog

 Value

 1

 For

 BACnet

38-41

Name

 Of

 Analog

 Value

 3

 For

 BACnet

38-42

Name

 Of

 Analog

 Value

 5

 For

 BACnet

38-43

Name

 Of

 Analog

 Value

 6

 For

 BACnet

38-44

Name

 Of

 Binary

 Value

 1

 For

 BACnet

38-45

Name

 Of

 Binary

 Value

 2

 For

 BACnet

38-46

Name

 Of

 Binary

 Value

 3

 For

 BACnet

38-47

Name

 Of

 Binary

 Value

 4

 For

 BACnet

38-48

Name

 Of

 Binary

 Value

 5

 For

 BACnet

38-49

Name

 Of

 Binary

 Value

 6

 For

 BACnet

38-50

Name

 Of

 Binary

 Value

 21

 For

 BACnet

38-51

Name

 Of

 Binary

 Value

 22

 For

 BACnet

38-52

Name

 Of

 Binary

 Value

 33

 For

 BACnet

38-53

Bus

 Feedback

 1

 Conversion

38-54

Run

 Stop

 Bus

 Control

38-58

Inverter

 ETR

 counter

38-59

Rectifier

 ETR

 counter

38-60

DB_ErrorWarnings

38-61

Extended

 Alarm

 Word

38-69

AMA_DebugS32

38-74

AOCDebug0

38-75

AOCDebug1

38-76

AO42_FixedMode

38-77

AO42_FixedValue

38-78

DI_TestCounters

38-79

Protect

 Func.

 Counter

38-80

Highest

 Lowest

 Couple

38-81

DB_SendDebugCmd

38-82

MaxTaskRunningTime

38-83

DebugInformation

38-85

DB_OptionSelector

38-86

EEPROM_Address

38-87

EEPROM_Value

38-88

Logger

 Time

 Remain

38-90

LCP

 FC-Protocol

 select

38-91

Motor

 Power

 Internal

38-92

Motor

 Voltage

 Internal

38-93

Motor

 Frequency

 Internal

38-94

Lsigma

38-95

DB_SimulateAlarmWarningExStatus

38-96

Data

 Logger

 Password

38-97

Data

 Logging

 Period

38-98

Signal

 to

 Debug

38-99

Signed

 Debug

 Info

Quick Guide

VLT

®

 HVAC Basic Drive Cascade Controller Quick Guide

26

MG18F402 - VLT

®

 is a registered Danfoss trademark

1

1

Summary of Contents for VLT series

Page 1: ...MAKING MODERN LIVING POSSIBLE Quick Guide VLT HVAC Basic Drive Cascade Controller...

Page 2: ......

Page 3: ...Terminals 10 1 3 9 Electrical Overview 11 1 4 Programming 12 1 4 1 Programming with the Local Control Panel LCP 12 1 4 3 The Start up Wizard for Open Loop Applications 13 1 5 Cascade Controller 21 1 5...

Page 4: ...a reinforced Protective Earth connection must be ensured by means of a min 10 mm Cu or an additional PE wire with the same cable cross section as the Mains wiring must be terminated separately Residua...

Page 5: ...ended Start While the frequency converter is connected to mains the motor can be started stopped using digital commands bus commands references or via the LCP or LOP Disconnect the frequency converter...

Page 6: ...4 H2 IP20 2 2 4 kW 3 5 4 hp 100 4 H3 IP20 5 5 7 5 kW 7 5 10 hp 100 4 H4 IP20 11 15 kW 15 20 hp 100 4 H5 IP20 18 5 22 kW 25 30 hp 100 4 H6 IP20 30 45 kW 40 60 hp 200 7 9 H7 IP20 55 75 kW 100 120 hp 20...

Page 7: ...595 23 4 635 25 495 19 5 239 31 5 200 7 9 242 9 5 8 5 H7 IP20 55 75 kW 100 120 hp 550 21 7 630 24 8 690 27 2 521 20 5 313 12 3 270 10 6 335 13 2 8 5 H8 IP20 90 kW 120 hp 660 26 800 31 5 631 24 8 375...

Page 8: ...nsions 95 mm2 1 3 5 Connecting to Mains and Motor The frequency converter is designed to operate all standard three phased asynchronous motors For maximum cross section on wires see 1 8 1 Mains Supply...

Page 9: ...8 03 02 01 06 05 04 2 3 4 130BB762 10 Illustration 1 3 IP20 380 480 V 30 45 kW 1 Line 2 Motor 3 Earth 4 Relays Table 1 10 Legend to Illustration 1 3 1 2 3 4 130BB763 10 Illustration 1 4 IP20 380 480 V...

Page 10: ...er kW Type RK5 Type RK1 Type J Type T Type gG 3x380 480 V 0 37 FRS R 10 KTS R10 JKS 10 JJS 10 10 0 75 FRS R 10 KTS R10 JKS 10 JJS 10 10 1 5 FRS R 10 KTS R10 JKS 10 JJS 10 10 2 2 FRS R 15 KTS R15 JKS 1...

Page 11: ...ains cable and between mains motor cable PLC Reinforced protective earth Illustration 1 6 EMC correct Electrical Installation FCM 106 NOTE For North America use metal conduits instead of shielded cabl...

Page 12: ...29 mode is set in 5 03 Digital Input 29 Mode PNP is default value Control terminals Illustration 1 9 shows all control terminals of the frequency converter Applying Start terminal 18 connection betwee...

Page 13: ...PNP Bus ter Bus ter RS 485 Interface RS 485 N PS 485 69 P RS 485 68 Com RS 485 61 PNP Source NPN Sink ON Terminated OFF Unterminated ON 1 2 240V AC 3A Not present on all power sizes Do not connect shi...

Page 14: ...it set up 4 Motor direction is shown to the bottom left of the display indicated by a small arrow pointing either clockwise or counterclockwise 5 The triangle indicates if the LCP is in status quick m...

Page 15: ...DIG IN COM DIG IN A OUT D OUT A OUT D OUT 18 19 27 29 42 55 50 53 54 20 12 01 02 03 04 05 06 R2 R1 0 10V Start 10V A IN A IN COM 130BB674 10 45 Reference Illustration 1 12 The wizard will initially b...

Page 16: ...o accept Automatic Motor Adaption Off Auto Motor Adapt OK Press OK Select Function of Relay 2 No function Select Function of Relay 1 0 No function Set Max Reference Hz Set Min Reference Hz AMA running...

Page 17: ...ency from nameplate data 1 24 Motor Current 0 01 10000 00 A Size related Enter motor current from nameplate data 1 25 Motor Nominal Speed 100 0 9999 0 RPM Size related Enter motor nominal speed from n...

Page 18: ...Low Limit Hz 0 0 400 Hz 0 Hz Enter the minimum limit for low speed 4 14 Motor Speed High Limit Hz 0 0 400 Hz 65 Hz Enter the maximum limit for high speed 4 19 Freq ncia M x de Sa da 0 400 Size relate...

Page 19: ...ck 0016 Hz 6 23 T54 high Current 13 30 A 6 25 T54 high Feedback 0050 0 01 s 20 81 PI Normal Inverse Control 0 Normal 20 83 PI Normal Inverse Control 0050Hz 20 93 PI Proportional Gain 00 50 1 29 Automa...

Page 20: ...o Motor 2 100 4 Enter the number of motor poles 1 40 For a Contra Eletromotriz em 1000RPM 10 9000 Size related Line Line RMS back EMF voltage at 1000 RPM 1 73 Flying Start 0 Disabled 1 Enabled 0 Selec...

Page 21: ...portional gain Quick control is obtained at high amplifi cation However if amplification is too great the process may become unstable 20 94 PI Integral Time 0 1 999 0 s 999 0 s Enter the process contr...

Page 22: ...it Hz 0 0 400 Hz 65 Enter the maximum limit for high speed 4 19 Freq nc ia M x de Sa da 0 400 Size related Enter the maximum output frequency value Table 1 19 Quick Menu Motor Set up Changes Made Chan...

Page 23: ...p is 3 In this operation the run time between pumps is equalized reducing the required pump maintenance and increasing reliability and lifetime of the system The alternation of the lead pump can take...

Page 24: ...nditions See 5 1 Digital Inputs Digital input commands Variable speed pump lead Fixed speed pumps lag Start SYSTEM START STOP Ramps up if stopped and there is a demand Staging if stopped and there is...

Page 25: ...if Load 50 0 Disabled 1 Enabled P25 56 Staging Mode at Alternation 1 Quick 0 Slow P25 58 Run Next Pump Delay 0 1 5 0 s 0 1 s P25 59 Run on Mains Delay 0 1 5 0 s 0 1 s Expression limit P25 20 Staging B...

Page 26: ...ailable One Pump Two Relay Modes when 25 57 Relays per Pump 2 130BD160 10 FC 111 24 V D IN D IN D IN OUT COM D IN OUT COM RS 485 P RS 485 N RS 485 10 V A IN A IN COM A OUT D OUT 12 18 19 20 27 29 61 6...

Page 27: ...3 Digital Outputs 5 30 Terminal 27 Digital Output 5 31 Terminal 29 Digital Output 5 34 On Delay Digital Output 5 35 Off Delay Digital Output 5 4 Relays 5 40 Function Relay 5 41 On Delay Relay 5 42 Off...

Page 28: ...25 06 Number of Pumps 25 2 Bandwidth Settings 25 20 Staging Bandwidth 25 21 Override Bandwidth 25 22 Fixed Speed Bandwidth 25 23 SBW Staging Delay 25 24 SBW Destaging Delay 25 25 OBW Time 25 27 Stage...

Page 29: ...motor or on motor terminals 17 4 Ctrl word TO X X No communication to frequency converter See parameter group 8 0 Comm General Settings 24 50 Fan Fault X X The fan is not working Only on 400 V 30 90...

Page 30: ...ink Temperature Low X This warning is based on the temperature sensor in the IGBT module Only on 400 V 30 90 kW units 69 1 Pwr Card Temp X X X The temperature sensor on the power card is either too ho...

Page 31: ...V A 1 3 2 4 4 1 5 8 7 9 9 9 13 2 17 1 25 3 34 0 40 7 46 8 67 1 80 3 99 0 116 0 161 0 194 0 Continuous 3x440 480 V A 1 1 2 1 3 4 4 8 6 3 8 2 11 0 14 0 21 0 27 0 34 0 40 0 52 0 65 0 80 0 105 0 130 0 16...

Page 32: ...97 9 98 0 97 8 98 1 97 9 98 1 97 9 97 8 97 7 98 98 2 97 8 97 9 Output current 50 C ambient temperature Continuous 3x380 440 V A 1 04 1 93 3 7 4 85 6 3 8 4 10 9 14 0 20 9 28 0 34 1 38 0 48 8 58 4 72 0...

Page 33: ...its between motor terminals U V W When a motor phase is missing the frequency converter trips and issues an alarm When a mains phase is missing the frequency converter trips or issues a warning depend...

Page 34: ...logic 1 NPN 14 V DC Maximum voltage on input 28 V DC Input resistance Ri Approx 4 k Digital output Programmable digital outputs 2 Terminal number 27 291 Voltage level at digital output 0 24 V DC Max...

Page 35: ...64 1 Overvoltage category III pollution degree 2 1 IEC 60947 parts 4 and 5 Control card 10 V DC outputA Terminal number 50 Output voltage 10 5 V 0 5 V Max load 25 mA A All inputs outputs circuits DC s...

Page 36: ...f the frequency converter is operated at high ambient temperature the continuous output current should be decreased For derating curve see VLT HVAC Basic Design Guide 1 9 2 Derating for Low Air Pressu...