Mains
Supply
3x200-240
V
AC
-
Normal
overload
110%
for
1
minute
IP20/Chassis
(B3+4
and
C3+4
may
be
converted
to
IP21
using
a
conversion
kit.
(Please
see
also
items
Mechanical
mounting
and
IP21/Type
1
Enclosure
kit
in
the
Design
Guide.))
B3
B3
B3
B4
B4
C3
C3
C4
C4
IP21/NEMA
1
B1
B1
B1
B2
C1
C1
C1
C2
C2
IP55/Type
12
B1
B1
B1
B2
C1
C1
C1
C2
C2
IP66/NEMA
4X
B1
B1
B1
B2
C1
C1
C1
C2
C2
Frequency
converter
Typical
Shaft
Output
[kW]
P5K5
5.5
P7K5
7.5
P11K
11
P15K
15
P18K
18.5
P22K
22
P30K
30
P37K
37
P45K
45
Typical
Shaft
Output
[HP]
at
208
V
7.5
10
15
20
25
30
40
50
60
Output
current
130BA058.10
Continuous
(3
x
200-240
V)
[A]
24.2
30.8
46.2
59.4
74.8
88.0
115
143
170
Intermittent
(3
x
200-240
V)
[A]
26.6
33.9
50.8
65.3
82.3
96.8
127
157
187
Continuous
kVA
(208
V
AC)
[kVA]
8.7
11.1
16.6
21.4
26.9
31.7
41.4
51.5
61.2
Max.
input
current
130BA057.10
Continuous
(3
x
200-240
V)
[A]
22.0
28.0
42.0
54.0
68.0
80.0
104.0
130.0
154.0
Intermittent
(3
x
200-240
V)
[A]
24.2
30.8
46.2
59.4
74.8
88.0
114.0
143.0
169.0
Additional
Specifications
Estimated
power
loss
at
rated
max.
load
[W]
4)
269
310
447
602
737
845
1140
1353
1636
Max.
cable
size
(mains,
motor,
brake)
[mm
2
/AWG]
2)
10/7
35/2
50/1/0
(B4=35/2)
95/4/0
120/250
MCM
With
mains
disconnect
switch
included:
16/6
35/2
35/2
70/3/0
185/
kcmil350
Weight
enclosure
IP20
[kg]
12
12
12
23.5
23.5
35
35
50
50
Weight
enclosure
IP21
[kg]
23
23
23
27
45
45
45
65
65
Weight
enclosure
IP55
[kg]
23
23
23
27
45
45
45
65
65
Weight
enclosure
IP66
[kg]
23
23
23
27
45
45
45
65
65
Efficiency
3)
0.96
0.96
0.96
0.96
0.96
0.97
0.97
0.97
0.97
Table
10.2
Mains
Supply
3x200-240
V
AC
Specifications
VLT
®
HVAC Drive Operating Instructions
66
MG11AH02 - VLT
®
is a registered Danfoss trademark
10
10