VLT
®
FCM Series
■
Handling the FC motor
Handling and lifting of VLT DriveMotors (FC motors)
must only be undertaken by qualified personnel. Full
product documentation and operating instructions
must be available together with tools and equipment
necessary for safe working practice. Eyebolts and/or
lifting trunnions supplied with the FC motor are
designed to support only the weight of the FC motor,
not the weight of the FC motor and any auxcillary
equipment attached to it. Be absolutely sure that
cranes, jacks, slings and lifting beams are capable of
carrying the weight of equipment to be lifted. Where
an eyebolt is provided with the motor, this should
be screwed down until its shoulder is firmly against
the face of the stator frame to be lifted.
FCM type
approx. weight (kg.)
FCM 305
11
FCM 307
13
FCM 307
17
FCM 315
20
FCM 322
26
FCM 330
28
FCM 340
37
FCM 355
56
FCM 375
61
■
Bearings
The standard solution is fixed bearing in the drive
side of the motor (shaft output side).
To avoid static indention, the storage area should be
vibration free. Where exposure to some vibration is
unavoidable, the shaft should be locked. Bearings
may be fitted with a shaft locking device which should
be kept in place during storage. Shafts should be
rotated by hand, one quarter of a revolution, at weekly
intervals. Bearings are despatched from the works
fully charged with lithium based grease.
Lubrication
Frame size
Lubrication type
Temperatur range
80-132
Esso unirex N3
-10 to + 1400°C
Bearing life
Maximum hours bearing life (Lna) expected at 80° C bearing temp. x 10
3
hours.
FCM
3000 min
-1
1500 min
-1
Horiz.
Vert.
Horiz.
Vert.
305-315
22
22
30
30
322-340
26
26
30
30
355-375
26
26
30
30
Lna bearing life is the adjusted, L10 life rating, taking account of: -Reliability -Material improvement -Lubrication
conditions.
Standard Bearing references and oil seals
FCM
Mounting
Poles (2/4)
Bearings
Oil seals - Bore x O/D x width in mm
Drive end
Non-drive end
305-307
All
All
6204 2Z-C3 6204 2RS-C3
20 x 30 x 7
311-315
All
All
6205 2Z-C3 6205 2RS-C3
25 x 35 x 7
322-330
All
All
6206 2Z-C3 6206 2RS-C3
30 x 42 x 7
340
All
All
6206 2Z-C3 6206 2RS-C3
30 x 42 x 7
355-375
All
All
6208 2Z-C3 6208 2RS-C3
40 x 52 x 7
■
Output shafts
Output shafts are produced from 35/40 Ton (460/540
MN/m
2
) tensile steel. Drive end shafts are provided
with a tapped hole to DIN 332 Form D and a
closed profile keyway as standard.
Balance
All motors are dynamically balanced, to ISO 8821with
key convention to IEC 60034-14.
MG.03.H3.02 - VLT is a registered Danfoss trademark
16