4.1.2 Setting LCP Display Values
The display area is activated when the frequency converter
receives power from mains voltage, a DC bus terminal, or an
external 24V supply.
The information displayed on the LCP can be customized for
user application.
••
Each display readout has a parameter associated
with it.
•
Options are selected in the quick menu
Q3-13
Display Settings
.
•
Display 2 has an alternate larger display option.
•
The frequency converter status at the bottom line
of the display is generated automatically and is not
selectable. See
6 Status Indication
for definitions
and details.
Display
Parameter number
Default setting
1.1
0-20
Motor RPMs
1.2
0-21
Motor current
1.3
0-22
Motor power (kW)
2
0-23
Motor frequency
3
0-24
Reference in percent
1
.
1
2
3
1
.3
1
.2
1
30BP04
1
.
1
0
799
RPM
Auto
Remote
Ramping
1
(
1
)
36.4
kw
7.
8
3
A
0.000
53.2 %
Status
1
.
1
1
.2
2
1
.3
1
30BP062.
1
0
207RPM
Auto
Remote
Running
1
(
1
)
24.4
kW
5.25A
6.9
Hz
Status
4.1.3 Display Menu Keys
Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation, and viewing fault log data.
1
30BP045.
1
0
Status
Q
ui
c
k
Menu
Main
Menu
A
l
arm
Log
Key
Function
Status
Press to show operational information.
•
In Auto mode, press and hold to toggle
between status read-out displays
•
Press repeatedly to scroll through each status
display
•
Press and hold [Status] plus [
Ⴃ
] or [
Ⴍ
] to
adjust the display brightness
•
The symbol in the upper right corner of the
display shows the direction of motor rotation
and which set-up is active. This is not
programmable.
Quick Menu
Allows access to programming parameters for
initial set up instructions and many detailed
application instructions.
•
Press to access
Q2 Quick Setup
for sequenced
instructions to program the basic frequency
controller set up
•
Press to access
Q3 Function Setups
for
sequenced instructions to program
applications
•
Follow the sequence of parameters as
presented for the function set up
Main Menu
Allows access to all programming parameters.
•
Press twice to access top-level index
•
Press once to return to the last location
accessed
•
Press and hold to enter a parameter number
for direct access to that parameter
Alarm Log
Displays a list of current warnings, the last 10
alarms, and the maintenance log.
•
For details about the frequency converter
before it entered the alarm mode, select the
alarm number using the navigation keys and
press [OK].
User Interface
VLT
p
Decentral Drive FCD 302 Operating Instructions
MG.04.F2.02 - VLT
p
is a registered Danfoss trademark
29
4