Service Manual FCD 300
Release 01/2003
24
Revise 08/01/2003 by DD Service Manager, Steffen Sundbæk
15.
Power up test / Control card test
The diagnosis of the Drive consists of two tests:
Power up test
Extended CC test
The Power up test is carried out every time the Drive is powered up and consists of:
Checksum validation of calibration data stored in EEPROM
Checksum validation of hardware and motor dependent parameters in EEPROM
The extended power card test can be activated via the parameter 620 and consist of:
Checksum validation of calibration data stored in EEPROM
Checksum validation of hardware and motor dependent parameters in EEPROM
Flash check
I/O test
If the extended test/power up test fails the Drive will display one of the following error
messages:
LCP2
fault
number
Internal
fault
number
LED
appearance
75% of the
time
LED
appearance
25% of the
time
Fault source
37
0
□□□□
■
■
■
■
■
■
No fault after Extended CC test or
Communication fault between CC and BMC2
38
1
□□□
■
■
■
■
■
□
■
FLASH fault
39
2
□□
■
□
■
■
■
□
■
■
RAM fault
40
3
□□
■
■
■
■
■
□□
■
Calibration constants area of CC EEPROM fault
41
4
□
■
□□
■
■
□
■
■
■
Information constants area of CC EEPROM fault
42
5
□
■
□
■
■
■
□
■
□
■
Motor control area of CC EEPROM fault
43
6
□
■
■
□
■
■
□□
■
■
Entire area of BMC2 EEPROM fault
44
7
□
■
■
■
■
■
□□□
■
Minimum SW version fault
45
8
■
□□□
■
□
■
■
■
■
Input /output test failed