Service Manual FCD 300
Release 01/2003
23
Revise 08/01/2003 by DD Service Manager, Steffen Sundbæk
14.
LED indications
No.
Name
Colour
OK status
Alternatives
Function
Off
Status is OK of the FCD
1
Status
Yellow
Off
On
Corresponding to parameter setting. For further
information see
design guide
- parameter number 26 and
DeviceNet manual for specific DeviceNet signalling.
On
OK status for the field bus used
(not relevant for non field bus device)
Slow flashing
Local operation or local stop
Fast flashing
Interface working, but no communication with master
(see also field bus manual for more specific info)
(not relevant for non field bus device)
2
Bus
Green
On
(If bus
option is
present, else
Off)
Off
Not OK status for the field bus used
(not relevant for non field bus device)
Off
No alarm is present
3
Alarm
Red
Off
Flashing
Flashing while trip/trip lock is present
Off
No warring is present
4
Warning
Yellow
Off
Flashing
Flashing while warning situation is present
On
The unit is powered from either line in or 24V DC
5
On
Green
On
Off
Power to the unit is missing from either line in or 24V
DC