10.2 General Technical Data
Mains supply (L1, L2, L3)
Supply voltage
380–480 V
±
10%, 525–690 V
±
10%
Mains voltage low/mains voltage drop-out:
During low mains voltage or a mains drop-out, the frequency converter continues until the intermediate circuit voltage drops
below the minimum stop level, which corresponds typically to 15% below the frequency converters lowest rated supply voltage.
Power-up and full torque cannot be expected at mains voltage lower than 10% below the frequency converters lowest rated
supply voltage.
Supply frequency
50/60 Hz ±5%
Max. imbalance temporary between mains phases
3.0% of rated supply voltage
True Power Factor (λ)
≥0.9 nominal at rated load
Displacement Power Factor (cos Φ) near unity
(>0.98)
Switching on input supply L1, L2, L3 (power ups)
maximum one time/2 min
Environment according to EN60664-1
overvoltage category III/pollution degree 2
The unit is suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical Amperes, 480/600 V
Motor Output (U, V, W)
Output voltage
0-100% of supply voltage
Output frequency
0-590 Hz
*
Switching on output
Unlimited
Ramp times
0.01-3600 s
*
Dependent on voltage and power
Torque Characteristics
Starting torque (Constant torque)
maximum 110% for 60 s
*
Starting torque
maximum 135% up to 0.5 s*
Overload torque (Constant torque)
maximum 110% for 60 s
*
*)
Percentage relates to the frequency converter's nominal torque
Cable lengths and cross sections
Max. motor cable length, screened/armoured
150 m
Max. motor cable length, unscreened/unarmoured
300 m
Max. cross section to motor, mains, load sharing and brake
*
Maximum cross section to control terminals, rigid wire
1.5 mm
2
/16 AWG (2x0.75 mm
2
)
Maximum cross section to control terminals, flexible cable
1 mm
2
/18 AWG
Maximum cross section to control terminals, cable with enclosed core
0.5 mm
2
/20 AWG
Minimum cross section to control terminals
0.25 mm
2
*)
Depending on voltage and power.
Digital inputs
Programmable digital inputs
4 (6)
Terminal number
18, 19, 27
1)
, 29
1)
, 32, 33
Logic
PNP or NPN
Voltage level
0-24 V DC
Voltage level, logic '0' PNP
<5 V DC
Voltage level, logic '1' PNP
>10 V DC
Voltage level, logic '0' NPN
>19 V DC
Voltage level, logic '1' NPN
<14V DC
Maximum voltage on input
28 V DC
Input resistance, R
i
aprrox. 4 kΩ
All digital inputs are galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
1)
Terminals 27 and 29 can also be programmed as output.
Specifications
VLT
®
AQUA Drive D-Frame
Operating Instructions
MG21A202 - VLT
®
is a registered Danfoss trademark
73
10
10