MG.10.O1.02 VLT is a registered Danfoss trademark
8
VLT
®
5000 INTERBUS
■
LEDs
There are 10 LEDs on the INTERBUS option card.
The LEDs are organized in two sets each having 5
LEDs. One set is visible through the top air outlet if
installed in a VLT®5000 bookstyle, the second set is
visible if installed in a VLT5000 Compact version.
TR
TR
UL
UL
CC/CR
CC/CR
RD
RD
BA
BA
IBS in
IBS Out
IBS in
IBS Out
MK 100A
MK 100B
MK
101A
MK
101B
Name
Indicates
Color On
OFF
CC/CR: Cable Check.
Green Incomming bus active
Incomming bus swicthed off
BA
Bus Active.
Green Bus active
Bus stopped
RD:
Status of outgoing bus. Red
Outgoing bus stopped
Outgoing bus active
TR:
Transmit/Receive.
Green PCP Communication running
NO PCP Communication running
UL:
Power OK.
Green Voltage within permissable range No Voltage
VLT 5000 Series is provided with different clamps and
brackets to enable a proper ground connec-aLso at
high frequency. low HF (high frequency) impedance.
This can be achived by connecting a large surface
area of the cabinet to Ground, for example by
mounting the VLT 5000 series on a conductive rear
plate.
Especially when having long distances between
the stations in a INTERBUS network it can be
necessary to use additional potential equalizing
cables, connecting the individual stations to the
same Ground potential.
Connectors
There are 4 connectors, arranged in groups of two.
MK100A and MK100B is to be used if installed in a
VLT®5000 Compact. MK101A and MK101B is used
if the INTERBUS Option is installed in a VLT®5000
Bookstyle. Only one group of connectors may be
used at a time.
Cable
routing
and
connectors