VLT

®

 3000 to 5000 Converter

MG.50.Q2.02 – VLT is a registered Danfoss trade mark

8

VLT 3000 Series

VLT 5000 series

500 Address

500 Adress

501 Baud rate

501Baud rate

502 Data read-out

009 Display line 2

503 Coasting

502 Coasting

504 Q-stop

503 Quick Stop

505 DC-brake

504 Dc-brake

506 Start

505 Start

507 Direction

506 Reversing

509 Set-up Select

507 Selection of Set-up

510 Digital Speed Select

508 Selection of Speed

511 Bus Jogging 1

509 Bus Jog 1

512 Bus Jogging 2

510 Bus Jog 2

513 Catch up/Slow down value

219 Catch up/Slow down value

514 Bus bit 4

No valid parameter

515 Bus bit 11/12

No valid parameter

516 Bus reference

No valid parameter

517 Store data values

No valid parameter

600 Index 1. Total Operating Hours

600 Operating Data: Operating Hours

600 Index 2. Running Hours

601 Operating Data: Hours Run Hours

600 Index 3. kWh counter

602 Operating Data: kWh Counter

600 Index 4. Number of Cut-ins

603 Operating Data: Number of Power-ups

600 Index 5. Number of Overheatings

604 Operating Data: Number of Overtemperatures

600 Index 6. Number of Overvoltages

605 Operating Data: Number of Overvoltages

604 Operation mode

620 Operation mode

650 VLT type

621 VLT type

700 U

a

 voltage

423 U1 voltage

701 f

a

 frequency

424 F1 frequency

702 U

b

 voltage

425 U2 voltage

703 f

b

 frequency

426 F2 frequency

704 U

c

 voltage

427 U3 voltage

705 f

c

 frequency

428 F3 frequency

706 U

d

 voltage

429 U4 voltage

707 f

d

 frequency

430 F4 frequency

708 U

e

 voltage

431 U5 voltage

709 f

e

 frequency

432 F5 frequency

Mapping list

Summary of Contents for VLT 3000 Series

Page 1: ...ed Danfoss trade mark VLT 3000 to 5000 converter Contents n Contents Introduction to VLT 3000 to VLT 5000 Converter Software version 2 Introduction 3 Configuration 3 Setup of the converter software 3...

Page 2: ...foss trade mark 2 VL T3000 to 5000 converter Manual Option card software version 17 1x Profibus DP Norm Software version This manual can be used for the VLT 3000 to 5000 converter software version 17...

Page 3: ...ly linked to the corresponding ramp up time parameter in VLT 5000 The GSD file in the VLT 5000 will also be as the VLT 3000 Please note that the converter software will only work on a Profibus DP Norm...

Page 4: ...4 Bus connection If LED 1 or LED 4 flashes the master has not recognized the LVT 5000 Check if Baud rate PPO type and station address are the same in the VLT 5000 as the VLT 3000 NOTE VLT 5000 has oth...

Page 5: ...Up Mode 019 Operating State at Power Up Local 015 Set up Selection 005 Programming Set up 100 Load 101 Torque characteristics 101 Speed Control 100 Configuration 102 Current Limit Control 308 311 and...

Page 6: ...ning High Current 214 Ramp type 206 Ramp type 215 Ramp Up Time 207 Ramp Up Time 1 216 Ramp Down Time 208 Ramp Down Time 1 217 Alternative Ramp Up Time 209 Ramp Up Time 2 218 Alternative Ramp Down Time...

Page 7: ...tion at Stop 314 Motor Preheat 122 Function at Stop 315 Motor thermal protection 128 Motor thermal protection 316 Relay ON delay 324 Relay 01 ON delay 317 Relay OFF delay 325 Relay 01 OFF delay 400 Bi...

Page 8: ...Store data values No valid parameter 600 Index 1 Total Operating Hours 600 Operating Data Operating Hours 600 Index 2 Running Hours 601 Operating Data Hours Run Hours 600 Index 3 kWh counter 602 Oper...

Page 9: ...53 Analogue Input 814 Data read out Analogue Input term 60 531 Data Read Out Terminal 60 Analogue Input 816 Alarm Parameters 538 Data Read Out Alarm Word 817 Relay 01 function 323 Relay 01 Output 818...

Reviews: