MG.50.Q2.02 – VLT is a registered Danfoss trade mark

VLT

®

 3000 to 5000 converter

Introduction

Introduction

This VLT 3000 to 5000 converter is a tool intended

for the conversion of a VLT 3000 to a VLT 5000,

which replaces the VLT 3000. The conversion is
possible for all VLT 3000s with the serial numbers

from  XXXXXXG265.

To purchase (obligatory):

- VLT 5000 175X
- Software version 17.1x incl. memory option for

  standard RS 485 communication,

  ordering no.

   175z3389

- Software version 17.1x incl. memory option and

  Profibus option,
  ordering no.

   175z4668

Optional:

- Backplate for 5001-5005 Compact IP 20, ordering

no.

   175Z2349

- Separate relay card, ordering no.

   175Z1814

If two high voltage relays are needed in VLT 5000 a

separate relay card must be purchased
Ordering  number

   176F1814

For the VLT 5001-5005 Compact IP20 the conversion
the purchase of a backplate (ordering number

175Z2349) is optional aswell.

Please notify some parameters in the VLT 3000 are
not supported in the VLT 5000 (see for example

page 5, parameter 107) and some VLT 5000

parameters can not be accessed via serial
communication.

Configuration

With the 17.1x software the VLT 5000 will react on

the Profibus network or the Standard Serial RS485

as a VLT 3000; it means that it is not necessary to
change anything in the PLC programme. A write

command to for example ramp up time in VLT 3000

is automatically linked to the corresponding ramp
up time parameter in VLT 5000. The GSD file in the

VLT 5000 will also be as the VLT 3000.

Please note that the converter software will only

work on a Profibus DP Norm network. It will not
work on a Sinec L2 or a Siemens DP network. You

can check your Profibus network either by the VLT

3000 or by the master.

After copying the baud rate, PPO type and station

address from the VLT 3000 to the VLT 5000, power
must be re-cycled to the VLT 5000 as these

parameters are only valid after power up. The
master should now recognize VLT 5000.

The two LED next to the Profibus connector should
now be solid green which indicates that

communication between master and slave is

established.

IM 308-B ver. 6

IM 308-C

This master supports

This master supports

Profibus DP Norm

Profibus DP Norm

We support Profibus DP Norm by VLT 3000 with a

software version that should be higher than  version

3.00. The software version number can be read
out in parameter 603, choice 3. The master must

be a Profibus DP Norm master. If a master from

Siemens S5 series is used the master must be an
IM-308C or IM-308B and higher or equal to version

6. All Siemens S7 series are Profibus DP Norm.

   

 

 

Setup of the converter software

Before VLT 3000 can be replaced with a VLT 5000

some parameters need to be setup in the VLT 5000.

Ensure that the parameters in the below table have
the same setting in VLT 5000 as in VLT 3000.

VLT 3000 

VLT 5000 

Par. 820 Baud Rate 

Par. 801 Baud rate 

Par. 904 PPO type 

Par. 904 PPO type 

Par. 918 Station Address 

Par. 918 Station Address 

 

Summary of Contents for VLT 3000 Series

Page 1: ...ed Danfoss trade mark VLT 3000 to 5000 converter Contents n Contents Introduction to VLT 3000 to VLT 5000 Converter Software version 2 Introduction 3 Configuration 3 Setup of the converter software 3...

Page 2: ...foss trade mark 2 VL T3000 to 5000 converter Manual Option card software version 17 1x Profibus DP Norm Software version This manual can be used for the VLT 3000 to 5000 converter software version 17...

Page 3: ...ly linked to the corresponding ramp up time parameter in VLT 5000 The GSD file in the VLT 5000 will also be as the VLT 3000 Please note that the converter software will only work on a Profibus DP Norm...

Page 4: ...4 Bus connection If LED 1 or LED 4 flashes the master has not recognized the LVT 5000 Check if Baud rate PPO type and station address are the same in the VLT 5000 as the VLT 3000 NOTE VLT 5000 has oth...

Page 5: ...Up Mode 019 Operating State at Power Up Local 015 Set up Selection 005 Programming Set up 100 Load 101 Torque characteristics 101 Speed Control 100 Configuration 102 Current Limit Control 308 311 and...

Page 6: ...ning High Current 214 Ramp type 206 Ramp type 215 Ramp Up Time 207 Ramp Up Time 1 216 Ramp Down Time 208 Ramp Down Time 1 217 Alternative Ramp Up Time 209 Ramp Up Time 2 218 Alternative Ramp Down Time...

Page 7: ...tion at Stop 314 Motor Preheat 122 Function at Stop 315 Motor thermal protection 128 Motor thermal protection 316 Relay ON delay 324 Relay 01 ON delay 317 Relay OFF delay 325 Relay 01 OFF delay 400 Bi...

Page 8: ...Store data values No valid parameter 600 Index 1 Total Operating Hours 600 Operating Data Operating Hours 600 Index 2 Running Hours 601 Operating Data Hours Run Hours 600 Index 3 kWh counter 602 Oper...

Page 9: ...53 Analogue Input 814 Data read out Analogue Input term 60 531 Data Read Out Terminal 60 Analogue Input 816 Alarm Parameters 538 Data Read Out Alarm Word 817 Relay 01 function 323 Relay 01 Output 818...

Reviews: