MG.50.Q2.02 – VLT is a registered Danfoss trade mark

VLT

®

 3000 to 5000 converter

Mapping list

The below listed VLT 3000 parameters in the left column have the corresponding VLT 5000 parameters as

shown in the right column. Please be notify that the opposite is not the case. the 5000 series using the LCP.

VLT 3000 Series

VLT 5000 series

000 Language Select

001 Language

001 Setup Selection Operation

004 Active Setup

002 Setup Copy

006 Copying of Setups

003 Operation Site

002 Local/remote Control

004 Local reference

Not available via serial com.

005 Display Value

008 Display Scaling of Motor Frequency

006 Local Reset

017 Local Reset of Trip

007 Local stop

Not available via serial com.

008 Local reversing

Not available via serial com.

009 Local Jogging

015 Local Jog

010 Local reference

Not available via serial com.

011 Reset Energy Counter

618 Reset of kWh Counter

012 Reset Hour Counter

619 Reset of Hour-Run Counter

014 Power-Up Mode

019 Operating State at Power-Up, Local

015 Set-up Selection

005 Programming Set-up

100 Load

101 Torque characteristics

101 Speed Control

100 Configuration

102 Current Limit Control

308, 311 and 314, Analogue input function

103 Motor power

102 Motor power

104 Motor voltage

103 Motor voltage

105 Motor frequency

104 Motor frequency

106 Automatic motor adaption

107 Automatic motor adaption

107 Motor current

105 Motor current

108 Motor magnetizing current

No valid parameter

109 Start voltage

No valid parameter

110 Start compensation

No valid parameter

111 U/f ratio

No valid parameter

112 Slip compensation

No valid parameter

113 Negative slip compensation

No valid parameter

114 Feedback type

308, 311 and 314, Analogue input function

115 Display Value at min. Feedback

414 Minimum Feedback

116 Display Value at max. Feedback

415 Maximum Feedback

117 Feedback Type

416 Reference/feedback Unit

121 Proportional Gain

440 Process PID Proportional Gain

122 Integral Time

441 Process PID Integral Time

123 Differentiation Time

442 Process PID Differentiation Time

124 Low Pass Filter

444 Process PID Low Pass Filter

Mapping list

Summary of Contents for VLT 3000 Series

Page 1: ...ed Danfoss trade mark VLT 3000 to 5000 converter Contents n Contents Introduction to VLT 3000 to VLT 5000 Converter Software version 2 Introduction 3 Configuration 3 Setup of the converter software 3...

Page 2: ...foss trade mark 2 VL T3000 to 5000 converter Manual Option card software version 17 1x Profibus DP Norm Software version This manual can be used for the VLT 3000 to 5000 converter software version 17...

Page 3: ...ly linked to the corresponding ramp up time parameter in VLT 5000 The GSD file in the VLT 5000 will also be as the VLT 3000 Please note that the converter software will only work on a Profibus DP Norm...

Page 4: ...4 Bus connection If LED 1 or LED 4 flashes the master has not recognized the LVT 5000 Check if Baud rate PPO type and station address are the same in the VLT 5000 as the VLT 3000 NOTE VLT 5000 has oth...

Page 5: ...Up Mode 019 Operating State at Power Up Local 015 Set up Selection 005 Programming Set up 100 Load 101 Torque characteristics 101 Speed Control 100 Configuration 102 Current Limit Control 308 311 and...

Page 6: ...ning High Current 214 Ramp type 206 Ramp type 215 Ramp Up Time 207 Ramp Up Time 1 216 Ramp Down Time 208 Ramp Down Time 1 217 Alternative Ramp Up Time 209 Ramp Up Time 2 218 Alternative Ramp Down Time...

Page 7: ...tion at Stop 314 Motor Preheat 122 Function at Stop 315 Motor thermal protection 128 Motor thermal protection 316 Relay ON delay 324 Relay 01 ON delay 317 Relay OFF delay 325 Relay 01 OFF delay 400 Bi...

Page 8: ...Store data values No valid parameter 600 Index 1 Total Operating Hours 600 Operating Data Operating Hours 600 Index 2 Running Hours 601 Operating Data Hours Run Hours 600 Index 3 kWh counter 602 Oper...

Page 9: ...53 Analogue Input 814 Data read out Analogue Input term 60 531 Data Read Out Terminal 60 Analogue Input 816 Alarm Parameters 538 Data Read Out Alarm Word 817 Relay 01 function 323 Relay 01 Output 818...

Reviews: