MG.50.Q2.02 – VLT is a registered Danfoss trade mark

VLT

®

 3000 to 5000 converter

VLT 3000 Series

VLT 5000 series

300 Brake Option

400 Brake Function

301 Start frequency

130 Start frequency

302 Start delay

120  Start delay

303 High starting torque

119 High starting torque

304 Mains failure

407 Mains failure

305 Flying start

445 Flying start

306 DC braking time

126 DC braking time

307 DC Brake Cut-in Frequency at Stop

127 DC Brake Cut-in Frequency

309 Reset Mode

405 Reset Function

310 Trip Delay at Current Limit

409 Trip Delay Torque
Note VLT 5000 is using a Torque limit and not a 
Current limit.

311 Trip Delay at Inverter Fault

410 Trip Delay Inverter

312 Max. Auto Restart Time

406 Automatic Restart Time

313 Motor Check

122 Function at Stop

314 Motor Preheat

122 Function at Stop

315 Motor thermal protection

128 Motor thermal protection

316 Relay ON-delay

324 Relay 01 ON-delay

317 Relay OFF-delay

325 Relay 01 OFF-delay

400 Binary Input 16

300 Terminal 16 Input

401Binary Input 17

301 Terminal 17 Input

402 Binary Input 18

302 Terminal 18 Input

403 Binary Input 19

303 Terminal 19 Input

404 Binary Input 27

304 Terminal 27 Input

405 Binary Input 29

305 Terminal 29 Input

406 Binary Input 32

306, 307 Terminal 32/33 Input

407 Signal Output 42

319 Terminal 42 Output

408 Signal Output 45

321 Terminal 45 Output

409 Relay output 01

323 Relay output 01

410 Relay output 04

326 Relay output 04

411 Analog reference type

203, 204, 205 Reference scaling

412 Term. 53 Analog input Voltage

309, 310 Analog input 53 scaling

413 Term. 60 Analog input mA

315, 316 Analog input 60 scaling

414 Time out

317 Time out

415 Time Out Function

318 Function after Time Out

Mapping list

Summary of Contents for VLT 3000 Series

Page 1: ...ed Danfoss trade mark VLT 3000 to 5000 converter Contents n Contents Introduction to VLT 3000 to VLT 5000 Converter Software version 2 Introduction 3 Configuration 3 Setup of the converter software 3...

Page 2: ...foss trade mark 2 VL T3000 to 5000 converter Manual Option card software version 17 1x Profibus DP Norm Software version This manual can be used for the VLT 3000 to 5000 converter software version 17...

Page 3: ...ly linked to the corresponding ramp up time parameter in VLT 5000 The GSD file in the VLT 5000 will also be as the VLT 3000 Please note that the converter software will only work on a Profibus DP Norm...

Page 4: ...4 Bus connection If LED 1 or LED 4 flashes the master has not recognized the LVT 5000 Check if Baud rate PPO type and station address are the same in the VLT 5000 as the VLT 3000 NOTE VLT 5000 has oth...

Page 5: ...Up Mode 019 Operating State at Power Up Local 015 Set up Selection 005 Programming Set up 100 Load 101 Torque characteristics 101 Speed Control 100 Configuration 102 Current Limit Control 308 311 and...

Page 6: ...ning High Current 214 Ramp type 206 Ramp type 215 Ramp Up Time 207 Ramp Up Time 1 216 Ramp Down Time 208 Ramp Down Time 1 217 Alternative Ramp Up Time 209 Ramp Up Time 2 218 Alternative Ramp Down Time...

Page 7: ...tion at Stop 314 Motor Preheat 122 Function at Stop 315 Motor thermal protection 128 Motor thermal protection 316 Relay ON delay 324 Relay 01 ON delay 317 Relay OFF delay 325 Relay 01 OFF delay 400 Bi...

Page 8: ...Store data values No valid parameter 600 Index 1 Total Operating Hours 600 Operating Data Operating Hours 600 Index 2 Running Hours 601 Operating Data Hours Run Hours 600 Index 3 kWh counter 602 Oper...

Page 9: ...53 Analogue Input 814 Data read out Analogue Input term 60 531 Data Read Out Terminal 60 Analogue Input 816 Alarm Parameters 538 Data Read Out Alarm Word 817 Relay 01 function 323 Relay 01 Output 818...

Reviews: