Drive enclosure size
Drive type
High Voltage @ 750 V DC, f
s
= 5 kHz
Low Voltage @ max current, f
s
= 5 kHz
I
out
nominal [A]
Filter selection
I
out
max [A]
Filter selection
NXP_1640 5
< 1965
3280
NXP_2060 5
< 2469
LDC-1150-6-0-Cxx
4120
2 x LDC-0700-6-0-Cxx
NXP_2300 5
< 2756
4200
Table 6: DC Filter Selection for Liquid-cooled 690 V Drives According to Energy Storage Requirements
Enclosure size
Drive
High Voltage @ 1025 V DC, f
s
= 5 kHz
Low Voltage @ max current, f
s
= 5 kHz
I
out
nominal [A]
Filter selection
I
out
max [A]
Filter selection
CH61
NXP_0170 6
< 199
LDC-0160-6-0-Cxx
340
LDC-0160-6-0-Cxx
NXP_0208 6
< 244
416
NXP_0261 6
< 309
500
CH62
NXP_0325 6
< 385
650
LDC-0340-6-0-Cxx
NXP_0385 6
< 456
770
NXP_0416 6
< 493
832
NXP_0460 6
< 545
LDC-0340-6-0-Cxx
920
NXP_0502 6
< 595
975
CH63
NXP_0590 6
< 699
1180
LDC-0700-6-0-Cxx
NXP_0650 6
< 770
1300
NXP_0750 6
< 889
1500
CH64
NXP_0820 6
< 972
1640
NXP_0920 6
< 1090
LDC-0700-6-0-Cxx
1840
NXP_1030 6
< 1221
2060
NXP_1180 6
< 1414
2360
LDC-1150-6-0-Cxx
NXP_1300 6
< 1558
2600
NXP_1500 6
< 1798
3000
NXP_1700 6
< 2040
3400
AJ377845348678en-000101 / 172F4785
12 | Danfoss A/S © 2023.01
Selection
DC Filters