A-2
Danfoss Turbocor Compressors Inc.
ECD-00007M Rev. 1
For a reference pressure of 356kPa at 283
º
K:
The referred power is determined to be:
PWR
ref
= 24.783*2.80-14.06 = 55.32 kW
The actual maximum power is:
PWRmax= 55.32 * (340 / 356) = 52.83 kW
The desired 3 phase power input is then :
Desired power = 52.83 * .562 = 29.69 kW