50
Annex
TFX INSTALLATION AND OPERATION MANUAL
6046279-001 March 2020
9.2 Technical data
This chapter contains information on the technical data of
the device.
9.2.1 Mechanical data
Table 38: Mechanical data
Mechanical data
Dimensions width/height/depth [mm]
Color
Black
Protection class
IP6K7
The protection class is only ensured
if all connectors of the device are
plugged in or covered with suitable
protection caps.
Temperature range
Standard mode:
Weight
Standard housing material
Pressure equalizing membrane
Yes
9.2.2 Electrical data
Table 39: Electrical data
Electrical data
Supply voltage range
terminal 30 DC
Power consumption, standard mode
Average power consumption
Controller
Memory expansion program flash 1 MB
Memory expansion data flash
Memory expansion FRAM
8 kB
Memory expansion SRAM
LEDs
RTC with back-up capacitor
Synchronization: GNSS/PROEMION
9.2.3 Interfaces
Table 40: Interfaces
Interfaces
CAN (number, ISO)
TFX Internal Antenna: 1 (ISO 11898-2/-5)
TFX External Antenna: 1 (ISO 11898-2/-5)
CAN specification
2.0 A/B
Max. CAN baud rate
1000 kbit/s
Mobile radio
TFX External Antenna: GSM/UMTS
Mobile radio frequency
range
Models TFX Internal Antenna, TFX External
Antenna:
2G/GSM/GPRS/Edge
3G/UMTS/HSPA 850/900/1900/2100MHz
Mobile radio transmission
rate
HSPA upload: 5.7 Mbit/s
HSPA download: 7.2 Mbit/s
Maximum mobile radio
transmission performance
33 dBm with GSM
33 dBm with GPRS
27 dBm with Edge
24 dBm with UMTS
24 dBm with HSPA
23 dBm with LTE (EU)
23 dBm with LTE (NA)
Satellite systems supported
GNSS: GPS Band L1 (Galileo / Glonass /
Beidou)
GPSfix: cold start <= 30s / warm start <= 1s
-130 dBm, > 6 satellites in viewing range)
USB
Digital OUT
1 digital output
DC
…
DC
Surge-proof up to 36 V
DC
Reverse voltage protection up to -36 V
DC
Analog IN
3 analog inputs
Measurement range: 0 V
DC
to 15 V
DC
Input resistance: 20 kΩ
Sampling rate: 20 Hz
Surge-proof up to 53 V
DC
Reverse voltage protection up to -53 V
DC
Tolerance: ± 1 % of measurement range end
value (at 25 °C)
Terminal 15
1 digital / analog input
Measurement range: 0 V
DC
to 78 V
DC
Input resistance: 103 kΩ
Sampling rate: 20 Hz
Digital switching threshold: 5.5 V
DC
DC
)
Surge-proof up to 100 V
DC
Reverse voltage protection up to -100 V
DC
Tolerance: ± 1 % of measurement range end
value (at 25 °C)