2.5 Mounting of O-ring and temperature sensor

One temperature sensor is factory mounted in the flow sensor. The other must be mounted in the 
opposite pipe relative to the flow sensor installation. Mounting pin available as accessory.

1.
Mount O-ring on 
pin.

2.
Insert pin with 
O-ring.

3.
Position O-ring.

4.
Remove pin.

5.
Moist and insert sensor 
probe. Tighten at torque 
12 ± 2 Nm.

To ensure accuracy and a tight seal the sensor installation should comply to EN1434-2 annex A:

Key

Threaded 

connection size A

Tapping bore

size B

18.5 mm

24 mm

G1

30.5 mm

G1¼

39mm

Note:

•  Tolerance on machined dimensions = ± 0.5 mm.
•  Pipe fittings for use with probe type DS (Direct Short).

: provision for security sealing.

Summary of Contents for SonoSafe

Page 1: ...1 09 2017 Danfoss VUIGB802 www heating danfoss com Installation User Guide SonoSelect and SonoSafe Energy Meters...

Page 2: ...rovided that the product is used in accordance with our instructions MID Directive 2014 32 EU Measuring Instrument Directive Module B D o EN1434 4 2015 Notified Body Force Certification 0200 performed...

Page 3: ...2 3 Flow sensor installation 5 2 4 Mounting orientation calculator 5 2 5 Mounting of O ring and temperature sensor 6 2 6 Communication Expansion modules 7 2 7 Installation of module cable 10 2 8 Batt...

Page 4: ...product 2 Installation 2 1 Preparation SonoSelect incorporates a tamper monitoring function If the calculator is opened the meter will set alarm E13 in display Don t open unless for adding communicat...

Page 5: ...llation Note Heat meters have red temp sensor in supply pipe and all cooling meters have blue temp sensor in supply pipe 2 3 Flow sensor installation Pipe position No limitations but avoid positions w...

Page 6: ...Mounting pin available as accessory 1 Mount O ring on pin 2 Insert pin with O ring 3 Position O ring 4 Remove pin 5 Moist and insert sensor probe Tighten at torque 12 2 Nm To ensure accuracy and a tig...

Page 7: ...r and pulse inputs The two pulse inputs can be programmed independently of each other see specification for pulse input module M Bus primary Lithium Thionyl Chloride battery half of AA size M Bus seco...

Page 8: ...2 pulse output module Once installed the meter will display the icon for wired communication in menu 2 of the display Pulse 1 energy terminal 16 terminal 17 Pulse 2 volume terminal 18 terminal 19 Pul...

Page 9: ...egram Walk by 2 minutes sending interval Accumulated energy Accumulated volume CurrentTime Hour counter factory Month log 1 last month log Can be changed via SonoApp Terminals and cables Communication...

Page 10: ...l to enclosure 4 Insert module following guide on PCBA cover Insert cable through hole connect cable and fix to screw terminals matching color and terminal numbers Fix cable s to cable relief Outer ja...

Page 11: ...n enclosure 3 Disconnect battery connector and remove battery 4 Short circuit battery connectors on PCB using a small flat head screwdriver 5 Connect new battery to PCB 6 Fit battery in enclosure 7 Cl...

Page 12: ...For SonoSelect Run installation check using Bluetooth dongle 014U1963 and SonoApp service tool 3 2 Supply return configuration Only available for SonoSelect Use Bluetooth dongle 014U1963 and SonoApp s...

Page 13: ...es as well as the current and historical values are stored in the calculator and can be displayed via the control button 4 1 Menu structure Hours Alarm Energy Volume LOOP 1 Supply temp Display test Al...

Page 14: ...ulse Return temperature Decimal emphasizer Temperature difference Units field 4 3 Alarms E01 System error E09 Low transducer signal E02 PCB error E10 Transducer error E03 Battery empty less than 1 mon...

Page 15: ...1 Module PCB 12 Bottom part PC 13 Temperature sensor 6 Disposal Item Material Disposal Battery AA cell Lithium thionyl chloride 620 mg Lithium Approved deposit for lithium batteries PCBA with display...

Page 16: ...16 Danfoss Energy Meters 2016 09 VUIGB802...

Reviews: