8 | © Danfoss | Energy Meters | 2018.01
VUIGB802
Installation & User Guide
SonoSelect and SonoSafe
2 pulse input module
Once installed the meter will display the icon for pulse inputs in menu 2 of the display. Accumulated
volume is only readable by communication. The two pulse inputs can be programmed independently of
each other.
Pulse value
0.001 m³ to 1 m³ per pulse
Voltage supply
≤ 6.0 V
Source current
≤ 0.1 mA
High level input threshold
≥ 2 V
Low level input threshold
≤ 0.5 V
Pull-up resistor
100 kΩ
Pulse length
≥100 ms
Maximum frequency
≤ 5 Hz
Pulse inputs
According to EN1434-2, section 7.1.5 (Classification of pulse input devices Class IB)
Battery life time
16+1 year
* Suitable for both electronic switch and Reed contact.
2 pulse output module
Once installed the meter will display the icon for wired communication in menu 2 of the display.
Pulse 1 (energy*)
+ terminal 16, - terminal 17
Pulse 2 (volume*)
+ terminal 18, - terminal 19
Pulse value*
Unit follow the display. Scaling follow least significant digit of the display
(default setting can be changed via SonoApp)
Pulse timing
Updates every 15 seconds
Polarity reversal:
Not possible, but can withstand -30V, max 27 mA without damage
Pulse length
≥100 ms
Pulse Pause:
≥100 ms
Voltage supply
3-30 V
Source current
≤ 27 mA
“ON” condition
U<2,0 @ 27mA
“OFF” condition
R>=6 MΩ
Maximum frequency
≤ 5 Hz
Pulse outputs
According to EN1434-2, section 8.2.3
(Classification of pulse output devices Class OB)
Battery life time
16+1 year
Cable length
Max 25 m
Alarms
E32 activates in meter if:
1) Module battery is empty
2) When no. of delayed pulses exceeds 5000 (incorrect scaling)
*Default setting. Can be changed via SonoApp.