![background image](http://html.mh-extra.com/html/danfoss/sono-3500-ct/sono-3500-ct_operating-instructions-manual_508247041.webp)
Commissioning
6.3 Start-up routine
SONO 3500 CT
Operating Instructions, 07/2019, VI.SH.P2.02
39
Menu
Parameter
Display example
Comments
Menu 5
Display test
Check of all segments. Dis-
play toggles between all
segments on/off.
6.3
Start-up routine
1. Power-up device.
2. Reset battery status indicator as described below.
Resetting the battery counter
Note
The reset can also be carried out via SIMATIC PDM.
When a new battery is installed and the plug is connected, the transmitter start-up routine
begins. The display shows the active software version, e.g. 2.03.
After ten seconds the message "reset.bat" will appear.
1. Press push button within six seconds to reset the internal battery counter. The message
"accept" will appear.
2. Press push button again within six seconds in order to reset the internal battery counter.
The battery indicator now shows full. If the push button is not pressed again, the battery
indicator will show "Low".
Figure 6-2
Reset internal battery counter
* Firmware version, here version 2.03