background image

DK

Oliepumpe type RSA

Tekniske data

Olietyper

Standard fyringsolie

og  bio olie (FAME)

Viskositetsområde

1,3 - 1,8 mm

2

/(cSt)

Omdrejningstal:
RSA 28
RSA 40/60/95/125

2400 - 3600 min

-1

1400 - 3600 min

-1

Trykområde:
Viskositet ≤ 1,8 mm

2

/s

- RSA 28/40/60/95/125
Viskositet > 1,8 mm

2

/s

- RSA 28
- RSA 40/60/95/125

5,5 - 12 bar

5,5 - 15 bar
5,5 - 21 bar

Fabriksindstilling:
RSA 28
RSA 40/60/95/125

7 bar

10 bar

Medietemperatur

-10 til +70 °C

Max. føde- og returtryk

4 bar

Tilslutninger (fig. 1)

P = dysetilslutning
 

RSA 28/40/60/95. . . . . . . . . . . . . . . . . . . . . . . G 1/8

 

RSA 125  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G 1/4

S = sugeledning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G 1/4
Fødetryksmåling  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G 1/4
R = returledning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G 1/4
M = trykmåling/udluftning  . . . . . . . . . . . . . . . . . . . . G 1/8

Bemærk!

Samtlige tilslutninger har anslået pakflade beregnet 
for standardfladepakninger.
Type RSA kan leveres såvel 1-strengs med omløbet “G” 
åbent (fig. 4) eller som 2-strengs med skruen “A” mon-
teret i omløbet “G” (fig. 5).
Startes en 2-strengs pumpe med blokeret returled-
ning, kan der opstå skader på pumpe og motor som 
følge af et kraftigt stigende pumpetryk med bloke-
ring til følge.
Ved 1-strengs drift med underliggende tank bør dyse-
ledningen monteres i udluftningsporten “M” og dyse-
porten “P” afblændes. Der skal her anvendes en af-
skærings-/lukkeventil på dyseledningen.

Omdrejningsretning

Set fra akselenden har en højregående pumpe om-
drejningsretning med uret, og en venstregående mod 
uret.

Udluftning

Ved 1-strengs anlæg udluftes pumpen ved 1-gangs 
opstart via udluftningsstudsen”M” (fig. 2).
Ved 2-strengs anlæg udlufter pumpen automatisk 
gennem returledningen.

Trykindstilling

Fig. 3 viser trykindstilling af en RSA pumpe. Maks. tryk 
er afhængig af:
•  Pumpetype
•  Viskositet
•  Trykområde

1-gangs opstart

Ved igangsætning af et anlæg med tomt rør-system 
bør RSA oliepumpen ikke køre uden olie i mere end 5 
min. Det forudsættes, at pumpen enten indeholder 
olie hidrørende fra fabrikken,  eller olie fra den foregå-
ende driftsperiode. Er dette ikke tilfældet, skal der 
spædes op med olie.

Anlæg

Installationen skal forsynes med forfilter efter gæl-
dende regler/praksis.

Sugeledningslængder

H = total tryk eller sugehøjde i meter
L = total sugeledningslængde i meter
Viskositeterne er angivet for normale handelskvalite-
ter ved 8 °C.

Medier

Pumpen er specificeret for drift med mineralske 
brændselsolier, henholdsvis medier med tilsvarende 
eller højere klassifikation.

Tilbehør

Til RSA-serien kan der leveres en løs flange inkl. 4 
skruer til montage på halsens anlægsflade, best.nr. 
070-0211.
RSA-typen kan anvendes som føde-/transportpumpe 
ved udskiftning af trykindstillingsfjederen.  
Trykindstillingsfjedre, område 1 - 5 bar, sammen med 
skilt med korrekt trykområdeangivelse har best.nr. 
070-0030.

GB

Oil pump type RSA

Technical data

Oil types

Standard fuel gas oil

and  bio oil (FAME)

Viscosity range

1.3 - 1.8 mm

2

/(cSt)

Speed:
RSA 28
RSA 40/60/95/125

2400 - 3600 min

-1

1400 - 3600 min

-1

Pressure range:
Viscosity ≤ 1.8 mm

2

/s

- RSA 28/40/60/95/125
Viscosity > 1.8 mm

2

/s

- RSA 28
- RSA 40/60/95/125

5.5 - 12 bar

5.5 - 15 bar
5.5 - 21 bar

Default settings:
RSA 28
RSA 40/60/95/125

7 bar

10 bar

Temperature of medium

-10 to +70 °C

Max. feed and return pressure

4 bar

Connections (fig. 1)

P = nozzle connection
 

RSA 28/40/60/95. . . . . . . . . . . . . . . . . . . . . . . G 1/8

 

RSA 125  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G 1/4

S = suction connection  . . . . . . . . . . . . . . . . . . . . . . . . G 1/4
Feed pressure measurement . . . . . . . . . . . . . . . . . . . G 1/4
R = return line  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G 1/4
M = pressure measurement/bleed  . . . . . . . . . . . . . G 1/8

Note!

All connection surfaces are spotfaced for standard 
gaskets.
Type RSA can be supplied as a 1-pipe pump with by-
pass “G” open (fig. 4) or as a 2-pipe pump with screw 
“A” fitted in bypass “G” (fig. 5).
If a 2-pipe pump is started with blocked return line, 
servere increase in pump pressure can damage the 
pump and motor and cause blocking.
For 1-pipe operation with underlying tank, the nozzle 
line should be connected to vent port “M”, with nozzle 
port “P” blanked off. In this case a shut-off valve must 
be installed in the  nozzle line.

Direction of rotation

The direction of rotation of a righthand pump is 
clockwise, a lefthand pump counterclock wise, when 
looking on the end of the shaft.

2800 min.

-1

RSA 28

RSA 40

RSA 60

RSA 95

RSA 125

H

m

Ø6

mm

Ø8

mm

Ø10
mm

Ø12
mm

Ø6

mm

Ø8

mm

Ø10
mm

Ø12
mm

Ø6

mm

Ø8

mm

Ø10
mm

Ø12
mm

Ø8

mm

Ø10
mm

Ø12
mm

Ø15
mm

Ø10
mm

Ø12
mm

Ø15
mm

Ø20
mm

4.0

23

73

100

100

16

51

100

100

11

34

83

100

21

51

100

100

39

81

100

100

3.5

22

69

100

100

15

48

100

100

10

32

78

100

20

48

99

100

36

76

100

100

3.0

20

64

100

100

14

45

100

100

9

30

73

100

18

45

93

100

34

71

100

100

2.5

19

60

100

100

13

42

100

100

9

28

68

100

17

42

86

100

32

66

100

100

2.0

18

55

100

100

12

39

95

100

8

26

63

100

16

38

80

100

29

61

100

100

1.5

16

51

100

100

11

36

87

100

7

24

58

100

14

35

73

100

27

56

100

100

1.0

15

46

100

100

10

33

80

100

7

22

53

100

13

32

67

100

25

51

100

100

0.5

13

42

100

100

9

29

72

100

6

20

48

99

12

29

60

100

22

46

100

100

0.0

12

38

92

100

8

26

64

100

6

17

43

88

11

26

54

100

20

41

100

100

-0.5

10

33

81

100

7

23

57

100

5

15

37

78

9

23

48

100

18

36

89

100

-1.0

9

29

70

100

6

20

49

100

4

13

32

67

8

20

41

100

15

31

77

100

-1.5

8

24

59

100

5

17

41

86

4

11

27

57

7

17

35

85

13

26

65

100

-2.0

6

20

46

99

4

14

34

70

3

9

22

46

6

14

28

69

10

22

53

100

-2.5

5

15

37

77

3

11

26

54

2

7

17

36

4

11

22

53

8

17

41

100

-3.0

3

11

26

54

2

8

18

38

2

5

12

25

3

7

15

38

6

12

29

91

-3.5

2

6

15

32

1

4

11

22

1

3

7

15

2

4

9

22

3

7

17

53

-4.0

1

2

4

9

0

1

3

5

0

1

2

4

1

1

3

6

1

2

5

13

Installation Guide, RSA

© Danfoss | 2019.04 | 3