PVB is with LS
A/B
shuttle valve
Code number 157B....
PVB is without LS
A/B
shuttle valve
-
9784
9783
9782
9781
-
-
B A
T
P
157-03.11
4-way, 3-position Throttled, open
neutral position
-
9760
9761
9762
9763
9764
-
-
-
-
-
-
-
-
4-way, 3-position Throttled, A
→
T in
neutral position
-
-
-
-
-
9794
-
-
-
-
-
-
-
-
4-way, 3-position B
→
T in neutral
position
-
-
-
-
-
9804
-
Standard PC spools
PVB is with LS
A/B
shuttle valve
Code number 157B....
PVB is without LS
A/B
shuttle valve
Press. compensated flow: l/min [US gal/min]
ISO symbol
Symbol
Press. compensated flow: l/min [US gal/min]
E
100
[26.4]
D
65
[17.2]
C
40
[10.6]
B
25
[6.6]
A
10
[2.6]
AA
5
[1.3]
AA
5
[1.3]
A
10
[2.6]
B
25
[6.6]
C
40
[10.6]
D
65
[17.2]
E
100
[26.4]
-
7033
7032
7031
7030
7035
4-way, 3-position
Closed neutral position, PC
→
A and B
7015
7010
7011
7012
7013
-
7134
7133
7132
7131
7130
7135
4-way, 3-position Throttled, open neutral position,
PC
→
A and B
7115
7110
7111
7112
7113
-
7064
7063
7062
7061
-
-
4-way, 3-position
Closed neutral position, PC
→
A
-
7040
7041
7042
7043
7044
Technical Information
PVG 32 Proportional Valve Group
Module selection chart
©
Danfoss | August 2017
520L0344 | BC00000038en-US0802 | 63