PVE characteristic - control by voltage
PVEP
control range
PVEU
fixed
7.5V
5V
2.5V
Closed loop control
The PVE variants PVEA/H/M/S/U/P and the PVED-CC/-CX has a closed loop control supported by a spool
position sensor that ensures integrity towards flow forces and oil viscosity.
Hysteresus for PVE variants*
2%
20%
PVEM
PVEA
+8
+6
+4
+2
0
-2
-4
-6
-8
4%
PVEH
157-504.10
PVES
~0%
* Hysteresis (control signal/spool travel) is indicated at rated voltage and f = 0.02 Hz. (one cycle = neutral
→
full A
→
full B
→
neutral)
The standard PVE’s are proportional activated actuator except PVEO which is on/off. The PVE’s have fault-
monitoring.
•
PVEU is available with PVEH and PVES hysteresis
•
PVEP, PVED-CC and PVED-CX are available with PVES hysteresis
The values are typical test data for exact ranges, see
PVE Technical Information
, 520L0553.
Technical Information
PVG 32 Proportional Valve Group
Electrical actuation
©
Danfoss | August 2017
520L0344 | BC00000038en-US0802 | 31