PVPF (Open Center) Inlet Modules - for Pumps with Fixed Displacement
Symbol
Description
BSP port
G1
SAE Port
1 5∕16-12
T0
P
T0
LS
LS
T P
LS
Refer to PVPE and Dummy
Spool in PVPF Acessories
P301 051
P
gage
P
P
P
P
Open center pump side module for pumps with fixed
displacement.
Max pump flow 250 l/min [66 US gal/min].
With pilot supply for PVE actuation.
With pilot gauge port.
12 bar
spring
*
161B5110
161B5510
20 bar
spring
*
161B5112
161B5512
Open center pump side module for pumps with fixed
displacement.
Max pump flow 250 l/min [66 US gal/min].
With pilot supply for PVH/PVHC actuation.
With pilot gauge port.
12 bar
spring
*
11013065
11013066
20 bar
spring
*
11013067
11013068
P301 052
T0
P
P
gage
P
P
P
P
T0
LS
LS
T P
Refer to PVPP in PVP Accessory Section
LS
Refer to PVPE and Dummy
Spool in PVPF Acessories
Open center pump side module for pumps with fixed
displacement.
Max pump flow 250 l/min [66 US gal/min].
With pilot supply for PVE actuation.
Accumulator port and facility for pilot shut-off valve
(PVPP).
12 bar
spring
*
161B5140
161B5540
20 bar
spring
*
161B5142
161B5542
Open center pump side module for pumps with fixed
displacement.
Max pump flow 250 l/min [66 US gal/min].
With pilot supply for PVH/PVHC actuation.
Accumulator port and facility for pilot shut-off valve
(PVPP).
12 bar
spring
*
11013071
11013072
20 bar
spring
*
11013073
11013074
*
Spring for pressure matching spool -
PVPF only.
*
PVPD (dummy spool)/PVPE/PVPH should be specified with any PVPF module. **PVPE/PVPH will electrically or hydraulically unload pump flow to tank
for a low pressure standby (refer to
Technical characteristics
on page 28).
PVPF Accessories for Pump Side Modules
Symbol
Description
Code Number
—
Dummy Spool
155G5041
P301 053
T0
P
T0
LS
LS
T P
PVPE
LS
P
gage
P
P
P
P
PVPE
Electrically actuated normally open, unloading valve
If PVPE or PVPH is not required the “Dummy Spool” must
be specified
12 V
155G5052
24 V
155G5054
P301 797
T0
P
P
gage
P
P
Ls
PVPH
Hydraulically actuated unloading valve
If PVPE or PVPH is not required the "Dummy Spool" must be
specified.
155G5061
*
*
Connection for external pilot pressure: available with G1/4 thread only. Pilot source should be independent of LS pressure (LS pressure may not be
enough to pilot PVPH).
Technical Information
PVG 100 Proportional Valve Group
Modules and code numbers
©
Danfoss | May 2018