Standard mounting vs. option mounting
Standard mounting – the PVM on the “A” port side of the PVB
B
A
Standard Mounted Work Section
LS holes
P301 065
Standard mounting is defined as installing the PVM on the “A” port side of the PVB. Because of this, the
PVE or PV cover (PVH, PVMD, PVMR, PVMF or PVHC) would be on the “B” port side of the valve.
Option mounting – the PVM on the “B” port side of the PVB
B
A
LS holes
P301 066
Option mounting is defined as installing the PVM on the “B” port side of the PVB. Because of this, the PVE
or PV cover (PVH, PVMD, PVMR, PVMF or PVHC) would be on the “A” port side of the valve.
The PVBS in PVG 100 are not symmetric. Because of this the “Load Sense” (Ls) holes in the PVBS main
spool must be installed so that they are on the “B” port side of the PVB.
Standard mounting spool (upper PVBS) vs. Option mounting spool (below PVBS)
LS holes
Before determining spool part numbers, determine whether the section will be standard or option
mounted. Standard and Option mounting only applies to a work section. Standard and option mounted
section can be used together in the same stack.
Technical Information
PVG 100 Proportional Valve Group
Mounting
38 |
©
Danfoss | May 2018
520L0720 | BC00000039en-US0502