PVG 100 with variable displacement pump schematic example
PVLP setting
in PVT should
be a minimum
of 30 bar above
setting on the
pump or external
relief valve
Inlet LS
Relief setting
should be set
below the PC
setting of the
pump by the
LS margin"
300
250
T0
P
Pp
P
gage
A
B
B
B
B
T
A
A
A
240
240
160
270 bar PC setting
with 20 bar LS margin
P301 790
Electrically actuated PVG 100, variable displacement pump, PVB 100 with integrated pilot operated check valves
P301 232
A
A
B
B
A
A
B
B
Technical Information
PVG 100 Proportional Valve Group
Hydraulic systems
34 |
©
Danfoss | May 2018
520L0720 | BC00000039en-US0502