PVED-CLS GPS configuration
Navigate to the GPS configuration section via System Navigator > Configuration > GPS Config
These parameters only apply if GPS is enabled. GPS Flow Limitation is used with auto-guidance to restrict
the maximum flow to steering cylinders as the vehicle speed increases. See Section 12.5 Vehicle Speed
Dependent Flow Command Limitation in the User Manual for more info.
Parameter
Conditions for value change
P3451
Set to desired flow limit [IR, 1000=100%] at 0 km/h (see graph below)
P3453
Set to desired vehicle speed in km/h (x-axis) at desired flow limit (P3455)
P3455
Set to desired vehicle speed in km/h (x-axis) at desired flow limit (P3453)
P3457
Set to desired vehicle speed in km/h (x-axis) at desired flow limit (P3459)
P3459
Set to desired flow limit (y-axis) at desired vehicle speed in km/h (P3457)
There are three subsets of GPS tuning that will need configuring if GPS is enabled.
Approve the parameters by following the steps in
PVED-CLS parameter acceptance
on page 8.
PVED-CLS example of GPS flow limitation
Application Guide
PVED-CLS startup guide
Parameter setting
©
Danfoss | October 2018
AB285975085591en-000101 | 33