
Parameter
Conditions for value changes
P3245
Set to match presence of redundant WAS signal
P3244
Set to match type of WAS signal: Analog, CAN, or None
P3246
Enable only if using uncompensated Analog WAS
P3247
Enable only if using uncompensated Analog WAS
P3250
Vehicle speed must be below this threshold to allow auto-guidance or AUX device to be enabled (speed measured in
km/h)
P3251
Vehicle speed must be below this threshold to allow for switching steering wheel programs (speed measured in km/h)
P3252
Vehicle speed must be above this threshold to use auto-guidance
P3253
PVED-CLS will go into safe-state mode if vehicle speed is above this threshold
P3241
Set to match presence of Safe On-Road Switch and electric architecture
P3239
Set to match presence of AUX device
P3240
Set to match type of AUX device
P3254
Set to IMD if using EHi-H
Approve the parameters by following the steps in
PVED-CLS parameter acceptance
on page 8.
Application Guide
PVED-CLS startup guide
Parameter setting
10 |
©
Danfoss | October 2018
AB285975085591en-000101