Assembling OSPE (continued)
Place O-rings (311) on plugs (209). Screw in the plugs
(209) using a 8 mm
Hex key.
45 ±5 Nm
The left side positioned plug is only present on OSPE’s
with priority valve integrated.
Replace the unit in the holding tool on steering column
end.
Place back up ring (303), O-rings (301, 302, 304), filter
(305) and locking ring (300) in/on cartridge (95). Screw in
cartridge (95) using special key Danfoss code 155L6494.
20 ±3 Nm.
After entire assembly of the steering valve, make the
pressure setting on a test panel according to valve
setting specification, see
Shock valves
on page 44.
Insert plastic protection plug (93).
Screw in the LS check valve (221) using a 3 mm
Hex
key.
3 ±0.5 Nm.
This check valve is not present in all OSPE’s.
Screw in the orifice (222) using a 3 mm
Hex key.
3 ±0.5 Nm.
This orifice is not present in all OSPE’s.
Service Manual
OSPE Steering Valve
Assembly
38
L1506577 • Rev 0001 • August 2015