MAGFLO
â
13
S
p
e
c
if
ic
a
ti
o
n
s
2. Specifications
Safety barrier & cleaning unit
Application
As combined unit with MAG 6000 only and MAG 1100 Ex/3100 Ex in the size
range
1
/
4
" - 12"
Ex approval
[EEx ia/ib] IIB
Cable parameter
Group
Capacity in
m
F
Inductance in mH
Electrode cable
IIB
£
31
£
80
Coil cable
IIB
£
0.5
£
8
Ambient temperature
During operation:
-
5 to 120
°
F
During storage:
-
5 to 160
°
F
rack mount
Enclosure material
Standard rack mount in aluminum/steel (DIN 41494)
Width: 4.75 inch
Height: 5.25 inch
Enclosure rating
NEMA 2
Mechanical load
1 G, 1-800 Hz sinusoidal in all directions to EN 60068-2-36
EMC performance
Emission
EN 50081-1 (Light industry)
Immunity
EN 50082-2 (Industry)
2.5.3
Safety barrier (ia/ib)
for sizes up to 12'’
Application
For use together with MAG 5000 and 6000 rack mount to clean the
electrodes on MAG 1100, MAG 3100 or MAG 5100 W.
NB
Must
not
be used with intrinsically safe systems
Cleaning voltage
(unloaded)
a.c. cleaning
60 V a.c.
d.c. cleaning
30 V d.c.
Cleaning period
60 sec. + 60 sec. pause period
Relay
Switch relay activated when cleaning is in progress
Load
42 V/2 A
Operation
Automatic
Yes
Manual
No
Indicator lamps
LEDs: "ON" and "CLEANING"
Supply voltage and
115-230 V a.c. +10% to
-
15%, 50-60 Hz, 7 VA cleaning, 5 VA stand by
power consumption
Ambient temperature
During operation:
-
5 to 120
°
F
During storage:
-
5 to 160
°
F
Rack mount
Enclosure material
Standard rack mount in aluminum/steel (DIN 41494)
Width: 4.75 inch
Height: 5.25 inch
Enclosure rating
NEMA 2
Mechanical load
1 G, 1-800 Hz sinusoidal in all directions to EN 60068-2-36
2.5.4