MAGFLO
S
p
e
c
if
ic
a
ti
o
n
s
6
2. Specifications
MAG 1100 and MAG 1100 Ex
Type
Flangeless sensor (Wafer)
Nominal size
1
/
4
",
3
/
8
",
1
/
2
", 1", 1
1
/
2
", 2", 3", 4"
3
/
8
",
1
/
2
", 1", 1
1
/
2
", 2", 3", 4"
1
/
4
",
3
/
8
",
1
/
2
", 1", 1
1
/
2
", 2", 3", 4"
Operating pressure
1
/
4
"-2
1
/
2
": 600 psi, 3": 560 psi,
1
/
4
"-2
1
/
2
": 600 psi, 3": 560 psi,
4": 450 psi
300 psi
4": 450 psi
Vacuum
1.5
×
10
-5
psi
0.3 psi
1.5
×
10
-5
psi
Temperature of
PFA
−
20
°
F to +265
°
F
medium
Ceramic
0
°
F to +300
°
F
−
5
°
F to +250
°
F
High temperature version
0
°
F to +400
°
F
Suitable for steam sterilization at 300
°
F
Temperature shock
(Duration > 1 min.):
Max. ±210
°
F momentarily
(Duration > 1 min.):
(Ceramic liner)
1
/
4
",
3
/
8
",
1
/
2
", 1":
1
/
4
",
3
/
8
",
1
/
2
", 1":
Max.
∆
T
≤
60
°
F/min.
Max.
∆
T
≤
60
°
F/min.
1
1
/
2
", 2", 2
1
/
2
": Max.
∆
T
≤
50
°
F/min.
1
1
/
2
", 2", 2
1
/
2
" : Max.
∆
T
≤
50
°
F/min.
3", 4" : Max.
∆
T
≤
40
°
F/min.
3", 4" : Max.
∆
T
≤
40
°
F/min.
(Duration
≤
1 min.,
(Duration
≤
1 min.,
followed by 10 min. rest):
followed by 10 min. rest):
1
/
4
",
3
/
8
",
1
/
2
", 1": Max.
∆
T
≤
175
°
F
1
/
4
",
3
/
8
",
1
/
2
", 1": Max.
∆
T
≤
175
°
F
1
1
/
2
", 2", 2
1
/
2
": Max.
∆
T
≤
160
°
F
1
1
/
2
", 2", 2
1
/
2
": Max.
∆
T
≤
160
°
F
3", 4": Max.
∆
T
≤
140
°
F
3", 4": Max.
∆
T
≤
140
°
F
Ambient temperature
Remote mount signal converter:
−
40
°
F to +210
°
F
Integral mount signal converter:
−
5
°
F to +120
°
F
Liner
Aluminum oxide Al
2
O
3
(ceramics)
Reinforced PFA (Teflon)
Aluminum oxide Al
2
O
3
(ceramics)
Electrodes
Platinum with gold/titanium brazing
Hastelloy C-276
Platinum with gold/titanium brazing
alloy
alloy
Enclosure
Stainless steel AISI 316L (1.4404)
Stainless steel AISI 316 (1.4436)
Stainless steel AISI 316L (1.4404)
Stainless steel AISI 316 (1.4436)
Terminal box
Standard
Fiberglass-reinforced polyamide
Fiberglass-reinforced polyamide
Stainless steel AISI 316L (1.4404)
(Remote installation only)
High temp.
Stainless steel AISI 316 (1.4436)
Stainless steel AISI 316L (1.4404)
Studs & nuts
Stainless steel AISI 304 (1.4301)
Stainless steel AISI 304 (1.4301)
Number and size to DIN 2501
Number and size to DIN 2501
Mating flanges
DIN 2501 (150-600 psi), ANSI B16.5, class 150 and 300 or equivalent
To DIN 2501 (150-600 psi),
ANSI B16.5,
class 150 and 300 or equivalent
Option
1/4'' & 3/8'': 1/2'' NPT threaded adaptor
Gaskets
Standard
EPDM (max. 300
°
F, 600 psi)
EPDM (max. 300
°
F, 600 psi)
Option
Graphite (max. 390
°
F, 600 psi)
Graphite (max. 390
°
F, 600 psi)
Option
PTFE (max. 210
°
F, 300 psi)
PTFE (max. 265
°
F, 300 psi)
Cable entries
4 pcs. PG 13.5
Enclosure rating
Standard
NEMA 4X / 6 (3 ft. submersion for 30 min)
Option
NEMA 6P (30 ft. continuous submersion)
Mechanical load (vibration)
18-1000 Hz random, 3.17 G rms in all directions to EN 60068-2-36
18-1000 Hz random in all directions
to EN 60068-2-36
Sensor: 3.17 G/
Integral mount Ex-d: 1.14 G
Test pressure
1200 psi (2
×
nominal)
600 psi (2
×
nominal)
1200 psi (2
×
nominal)
Ex approvals
EEx [ia/ib] IIB T4-T6/
DEMKO, No. 97D.121909X
Excitation frequency
1
/
4
" - 2
1
/
2
": 15 Hz
3
/
8
" - 2
1
/
2
": 15 Hz
1
/
4
" - 2
1
/
2
": 15 Hz
programmable
3", 4": 7.5 Hz
3", 4": 7.5 Hz
3", 4": 7.5 Hz
2.
Specifications
2.1 Sensor MAG 1100 and MAG 1100 Ex
MAG 1100 Ceramic
MAG 1100 PFA
MAG 1100 Ex