Important
▪
The nodeID set in the WAKE_UP_INTERVAL_SET command must be for a permanently listening
device which reponds to the commands sent from
living connect
®. This means PC's with USB
sticks will only work if the PC is never turned off. If the controller is turned off for extended peri-
odes,
living connect
® will use the batteries too fast.
▪
To preserve battery - Wake_Up_intervals should not be set to less than 5 min. Increasing the
time between intervals will increase battery life but can reduce user satisfaction due to long re-
action times.
▪
Although
living connect
® supports single commands, multi commands must always be used to
ensure two years battery lifetime.
▪
If multiple thermostats are installed in the same room it is important that the controller ensures
that they all have the same schedule and the same setpoint.
▪
In order to ensure proper routing with battery operated devices, the controller must support
SUC.
living connect® and Z-
Wave repeaters
living connect
® may benefit if more mains powered Z-Wave devices are added to a Z-Wave network.
Mains powered Z-Wave devices improve the reliability of a Z-Wave network as they can act as re-
peaters and thus provide alternate routes for communication.
Implemented Z-Wave de-
vice classes
Z-Wave Device Classes
Device Class Implemented
Generic Device
GENERIC_TYPE_THERMOSTAT
Specific Device
SPECIFIC_TYPE_SETPOINT_THERMOSTAT
Supported and controlled
Z-Wave command classes
Z-Wave Command Classes Supported
Description
COMMAND_CLASS_BATTERY
Get current battery status of
living connect
®.
COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE
Control a temperature offset to the ther-
mostat setpoint of
living connect
®. The tem-
perature offset is defined by schedules and
schedule overrides.
COMMAND_CLASS_CLOCK
Set or get the current
living connect
® clock.
COMMAND_CLASS_MANUFACTURER_PROPRIETARY
Special command used for communication
with a Danfoss Link system.
COMMAND_CLASS_MANUFACTURER_SPECIFIC
Get manufacturer ID of system.
COMMAND_CLASS_MULTI_CMD
A special Z-Wave command used by
living
connect
® to encapsulate multiple com-
mands in one command and thereby con-
serve battery life.
COMMAND_CLASS_PROTECTION
Set or get
living connect
® local protection
mode.Possible local protection values are:
0 = no protection
2 = fully locked (tamperproof)
COMMAND_CLASS_THERMOSTAT_SETPOINT
Set or get current thermostat setpoint of
living connect
®.Heating setpoint is the only
supported setpoint type.
COMMAND_CLASS_VERSION
Get version of product and command
classes.
COMMAND_CLASS_WAKE_UP
A special Z-Wave command used by
living
connect
® to synchronize communication
with its controller.
Data Sheet
living connect®, Z-Wave Certified Electronic Radiator Thermostat
Danfoss Heating Solutions
VDHMB202
© Danfoss
09/2011