background image

8

11/2013 

VIIDH102 

Danfoss Heating Solutions

1.7 Installing 

living connect®

1.

2.

living connect

®

 must be in Installation Mode 

to be fixed correctly onto the valve. This is 

indicated by a large, flashing 

M

 in the display.

Installation Mode can be selected by pressing  

 for 3 seconds until 

M

 is displayed, then 

release and press   again.

Screw 

living connect

®

 onto the adapter and 

tighten by hand (max. 5 Nm).

While slightly pressing forward, turn 

living 

connect

®

 clockwise untill it locks, then tighten.

3.

4.

Press   to fix 

living connect®

.

Icons for Network Connection and Alarm are 

flashing, indicating 

living connect®

 is ready for 

connection with Danfoss Link™ CC.

1.8  Automatic adjustments

During the first night of operation 

living connect®

 will shut off the radiator heat and then open 

again to detect the exact opening point of the valve. This will allow 

living connect®

 to control the 

heat as efficiently as possible. If necessary, the proce dure is repeated once a night for up to a week. 

You might experience the valve being warm dur ing the adjustment procedure, regardless of the 

room temperature. 

Intelligent Control (Forecast)

During the first week of operation 

living connect

®

 learns when it is necessary to start heating the 

room in order to reach the correct temperature at the correct time.

The intelligent control will continuously adjust the heating time compared to seasonal tempera-

ture changes.

Using Saving Program requires that your heating system has enough heat for a short period during 

heat up. If your experience problems you should contact your installer.

Installation Guide 

living connect®

Summary of Contents for living connect

Page 1: ...Danfoss Heating Solutions VIIDH102 11 2013 1 Installation and User Guide living connect Electronic Radiator Thermostat...

Page 2: ...8 1 8 Automatic adjustments 8 1 9 Removing living connect 9 1 10 Resetting living connect to default settings 9 1 11 Removing an adapter from living connect 10 2 Technical specifications 11 Pay a vis...

Page 3: ...g living connect to a Danfoss Link system 4 1 Configuring rooms in Danfoss Link CC 12 4 2 Connecting living connect to Danfoss Link CC 12 4 3 Testing the connection 14 5 Additional settings 5 1 Adjust...

Page 4: ...e mounted adapter for Danfoss RA valves two alkaline AA batteries a 2 mm Allen key and a Quick Guide in languages English German Danish Dutch French Polish Swedish and Finnish living eco Quick Start G...

Page 5: ...are available as accessories Adapter type Code no Adapter Valve For Danfoss RA valves 014G0251 For M30 x 1 5 K valves 014G0252 For Danfoss RAV valves 014G0250 34 For Danfoss RAVL valves 26 For Danfoss...

Page 6: ...the 2 mm Allen key Adapter for M30 x 1 5 K valves 1 2 Place the K adapter on the valve as shown Hand tighten the K adapter max 5 Nm Adapter for RAV valves accessory 1 2 Click the inner adapter on the...

Page 7: ...ol is displayed approx one month before the batteries run out After approx two weeks the symbol will flash 14 times from 19 00 to 21 00 hrs Before the batteries run out living connect will leave the v...

Page 8: ...f operation living connect will shut off the radiator heat and then open again to detect the exact opening point of the valve This will allow living connect to control the heat as efficiently as possi...

Page 9: ...dicate that Installation Mode is activated 3 4 Remove the battery cover and the batteries Insert the Allen key or similar into the hole to lock the adapter ring Turn counterclockwise to unscrew living...

Page 10: ...t a small hex key or similar into the locking hole to lock the adapter ring 3 4 With the hex key locking the adapter ring turn the adapter in the shown direction Put back the battery cover Mount livin...

Page 11: ...ttery level is critical the whole display will flash Ambient temperature range 0 to 40 C Transportation temperature range 20 to 65 C Maximum water temperature 90 C Temperature setting range 4 to 28 C...

Page 12: ...Danfoss Link system 4 1 Configuring rooms in Danfoss Link CC Make sure that the room in which living connect has been installed has been configured in Danfoss Link CC see installation guide for Danfo...

Page 13: ...r No 6 Heating System Mode Decide what the heating system prioritizes Heating with low return temperature recommended for district heating Fast heating with warm radiators recommended for boilers Mode...

Page 14: ...m and antenna symbols will both be flashing Refer to Technical questions at www living danfoss eu 5 Additional settings 5 1 Adjusting to radiator room conditions Press for at least 3 seconds until M i...

Page 15: ...s preventing it from detecting the decreasing temperature 5 3 Automatic valve exercising To keep the radiator valve functional and at its best living connect automatically exercises the valve every Th...

Page 16: ...n and User Guide living connect Danfoss A S Haarupvaenget 11 DK 8600 Silkeborg Denmark Phone 45 7488 8000 Fax 45 7488 8100 www danfoss com www living danfoss eu Installer VIIDH102 Produced by Danfoss...

Reviews: